第108回大会 2014年9月 釜山(大会長:遠藤真広)(The 7th KOREA-JAPAN Joint Meeting on Medical Physics)

2021年01月19日

7516 部会108 韓国 14 09 Imaging 1 Takahiro KONDO Department of Radiation Technology, Hiroshima Wako Group Futaba Hospital, Japan EVALUATION OF X-RAY COMPUTED TOMOGRAPHY RADIATION DOSE PROFILE USING POLYMER GEL DOSIMETER * Shin-Ichiro HAYASHI, Shuji USUI, Hiraku KAWAMURA, Kazunobu KOSHI, Akinori YAMANE, Takashi ENDO, Kei HIMENO, Takahiro TOMINAGA
7517 部会108 韓国 14 09 Imaging 1 Seyjoon PARK Department of Proton Therapy Center, National Cancer Center, Korea, Republic of WATER EQUIVALENT PATH LENGTH MEASUREMENT FOR PROTON RADIOGRAPHY AND PROTON COMPUTED TOMOGRAPHY USING RANGE SHIFTING WATER PHANTOM * Chiyoung JEONG, Jiseoc LEE, Seungryong CHO, Jae-Ik SHIN, Jong Hwi JEONG, Haksoo KIM, Me Young KIM, Dongho SHIN, Young Kyung LIM, Se Byeong LEE
7518 部会108 韓国 14 09 Imaging 1 Kosuke MATSUBARA Department of Quantum Medical Technology, Kanazawa University, Japan OPERATING CHARACTERISTICS OF TUBE CURRENT MODULATION TECHNIQUES WHEN SCANNING SIMPLE-SHAPED PHANTOMS * Pei-Jan Paul LIN, Atsushi FUKUDA, Kichiro KOSHIDA
7519 部会108 韓国 14 09 Imaging 1 Kyeong Yun KIM Department of Department of Biomedical Sciences, Seoul National University, Korea, Republic of EVALUATION OF MAXIMUM LIKELIHOOD RECONSTRUCTION OF ACTIVITY AND ATTENUATION USING LISTMODE DATA WITH TOF INFORMATION GENERATED BY MONTE CARLO SIMULATION * Jae Sung LEE
7520 部会108 韓国 14 09 Imaging 1 Hiroyuki MUKAI Department of Graduate School of Engineering, Hosei University, Japan ESTIMATION OF ACTIVITY IN SMALL ANIMAL MULT-ISOTOPE SPECT STUDY * Yuta ICHIMURA, Koichi OGAWA, Izumi O UMEDA, Hirofumi FUJII
7521 部会108 韓国 14 09 Imaging 1 Min Kyoung CHA Department of Department of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul, Korea, Republic of,, Korea, Republic of A COMPARATIVE STUDY BETWEEN EVALUATION METHODS ON QUALITY CONTROL PROCEDURE OF ACCURACY OF PET/CT REGISTRATION * Hyun Soo KO, Jae Kwang RYU, Woo Young JUNG, Bo Young CHOE
7522 部会108 韓国 14 09 Imaging 1 Seung Kwan KANG Department of Nuclear Medicine, Seoul National University Hospital, Korea, Republic of KINETIC PARAMETER ESTIMATION USING PARTICLE SWARM OPTIMIZATION IN PET * Seongho SEO, Sujin KIM, Jae Sung LEE
7523 部会108 韓国 14 09 Imaging 1 Do-Wan LEE Department of Department of Biomedical Engineering, and Research Institute of Biomedical Engineering, The Catholic University of Korea College of Medicine, Korea, Republic of ALTERED GLUTAMINE AND GLUTAMATE SIGNALS IN REPEATED INTERMITTENT ETHANOL-EXPOSED RAT HIPPOCAMPUS AS ASSESSED BY EX VIVO 1H NMR SPECTROSCOPY * Kyu-Ho SONG, Bo-Young CHOE
7524 部会108 韓国 14 09 Imaging 1 Hunnyun KIM Department of Biomedical Engineering, College of Medicine, The Catholic University, Korea, Republic of ALTERATION OF NEURONAL GLUCOSE METABOLISM IN RAT BRAIN UPON FOREPAW ELECTRICAL STIMULATION AT DIFFERENT FREQUENCIES * Won Beom JUNG, Jin Young JUNG, Geun Ho IM, Jung Hee LEE, Bo-Young CHOE
7525 部会108 韓国 14 09 Dosimetry 1 Seonghoon JEONG Department of Kyung Hee University Hospital at Gang-Dong, Radiation Oncology, Korea, Republic of DOSIMETRIC CHARACTERISTICS FOR PRODUCTS WITH DIFFERENT DENSITIES MADE BY 3D-PRINTER * Weonkuu CHUNG, Dong Wook KIM, Jiwon SUNG, Jihye KOO, Myeonggeun YOON
7526 部会108 韓国 14 09 Dosimetry 1 Suoh SAKATA Department of Dose Calibration Center, Association for Nuclear Technology in Medicine, Japan A CALIBRATION SYSTEM OF THERAPY-LEVEL DOSIMETER IN TERMS OF ABSORBED DOSE TO WATER BY ANTM * Kou YMASHITA, Nobuhiro TAKASE, Masahiro HOTEIDA, Yosuke SASAKI, Hiroaki OKUMURA, Kaori YAJIMA, Hideyuki MIZUNO, Katuhisa NARITA, Akifumi FUKUMURA
7527 部会108 韓国 14 09 Dosimetry 1 Kwang-Ho CHEONG Department of Dept. of Radiation Oncology, Hallym University College of Medicine, Korea, Republic of STATISTICAL QUALITY CONTROL FOR VOLUMETRIC MODULATED ARC THERAPY (VMAT) DELIVERY USING MACHINE LOG DATA * Me-Yeon LEE, Sei-Kwon KANG, Jai-Woong YOON, Soah PARK, Taejin HWANG, Haeyoung KIM, Kyoung Ju KIM, Taejin HAN, Hoonsik BAE
7528 部会108 韓国 14 09 Dosimetry 1 Wataru MAEHANA Department of Radiation Oncology, Kanagawa Cancer Center, Japan EVALUATION OF THE PERFORMANCE OF THE AUTOMATICALLY RADIATION ISOCENTER ANALYSIS SOFTWARE * Masahiko KUROOKA, Kenji SHIOIRI, Yuji TOKIYA, Daisuke KAWAI, Shogo HATANAKA, Shinsuke IDE, Kouzo SAKATA, Yuko NAKAYAMA
7529 部会108 韓国 14 09 Dosimetry 1 Ji-Hye SONG Department of Biomedical engineering, Research institute of biomedical engineering, The catholic university of korea, Korea, Republic of THE EFFECT OF LOW DOSE THRESHOLD ON VOLUMETRIC MODULATED ARC THERAPY DOSIMETRIC ACCURACY USING GAMMA EVALUATION ACCORDING TO VARIOUS CRITERIA * Min-Joo KIM, So-Hyun PARK, Seu-Ran LEE, Min-Young LEE, Tae-Suk SUH
7530 部会108 韓国 14 09 Dosimetry 1 Daisuke KAWAI Department of Radiation Oncology, Kanagawa Cancer Center, Japan EVALUATION OF THE DEVIATION BETWEEN THE RADIATION IC AND THE COORDINATES OF EXACTRAC X-RAY SYSTEM USING THE IN-HOUSE W-L PHANTOM * Wataru MAEHANA, Masahiko KUROOKA, Kenji SHIOIRI, Shogo HATANAKA, Yuji TOKIYA, Yoichiro OHTA, Shinsuke IDE, Kouzo SAKATA, Yuko NAKAYAMA
7531 部会108 韓国 14 09 Dosimetry 1 Kwangwoo PARK Department of Dept. of radiation oncology, College of Medicine, Yonsei University, Korea, Republic of DETERMINATION OF THE SMALL FIELD CORRECTION FACTORS FOR CYLINDRICAL IONIZATION CHAMBERS * Jino BAK, Won Hoon CHOI, Suk Won PARK
7532 部会108 韓国 14 09 Dosimetry 1 Yasumasa KAKINOHANA Department of Radiology, University of the Ryukyus, Japan DOSIMETRIC COMPARISON BETWEEN PORTRAIT AND LANDSCAPE ORIENTATIONS IN RADIOCHROMIC FILM DOSIMETRY * Takafumi TOITA, Gorou KASUYA, Takurou ARIGA, Jouichi HEIANNA, Sadayuki MURAYAMA
7533 部会108 韓国 14 09 Dosimetry 1 Kyung Hwan CHANG Department of Radiation Oncology, College of Medicine, Korea University, Korea, Republic of DEVELOPMENT OF 3D DOSE EVALUATION SOLUTION FOR OFF-LINE DOSE GUIDED ADAPTIVE RADIOTHERAPY IN MULTI-MODALITY IMRT TECHNIQUES * Suk LEE, Yuanjie CAO, Jang Bo SHIM, Kwang Hyeon KIM, Suk Woo CHOI, Jin Soo KO, Hong JEONG, Sam Ju CHO, Sang Hoon LEE, Yura CHO, Nam Kwon LEE, Jung Ae LEE, Dae Sik YANG, Won Sup YOON, Young Je PARK, Chul Yong KIM
7534 部会108 韓国 14 09 Imaging 2 Kohei SHIMOMURA Department of Radiological Service, Kinki University Hospital, Japan ANALYSIS OF PHYSICAL DENSITY AND WEIGHT FRACTION FOR HUMAN TISSUE MATERIALS USING DUAL ENERGY COMPUTED TOMOGRAPHY * Yuki KONO, Yoshiyuki ASAI, Masahiko OKUMURA, Nobumasa UEMURA, Kenji MATSUMOTO, Tomoko HYODO, Takamichi MURAKAMI, Yasumasa NISHIMURA, Hajime MONZEN, Fujio ARAKI
7535 部会108 韓国 14 09 Imaging 2 Hidetake HARA Department of Medical Engineering and Technology, Kitasato University, Japan VIRTUAL MONOCHROMATIC IMAGING IN DUAL-SOURCE DUAL-ENERGY CT FOR VISUALIZATION OF ACUTE ISCHEMIC STROKE * Hiroshi MURAISHI, Hiroki MATSUZAWA, Toshiyuki INOUE, Shinji ABE, Hitoshi SATOH, Yasuo NAKAJIMA
7536 部会108 韓国 14 09 Imaging 2 Juhye KIM Department of Department of Medical Sciences, Ewha Womans University, Seoul, Korea, Korea, Republic of DESIGN AND EVALUATION OF NEW METAL ARTIFACT REDUCTION ALGORITHM USING EDGE PRESERVING SMOOTHING FILTER FOR CT IMAGE * Haewon NAM, Rena LEE
7537 部会108 韓国 14 09 Imaging 2 Sung Won KIM Department of Electrical and Computer Engineering, Seoul National University, Korea, Republic of A CAPACITIVE CHARGE MULTIPLEXING METHOD FOR MULTIANODE PHOTOMULTIPLIER TUBE BASED PET DETECTORS * Guen Bae KO, Jeong-Whan SON, Jun Yeon WON, Jae Sung LEE
7538 部会108 韓国 14 09 Imaging 2 Shinya SONODA Department of Cosmic-Ray Group Dept. of Physics, Kyoto Univ., Japan THE PERFORMANCE EVALUATION OF ELECTRON TRACKING COMPTON CAMERA FOR MEDICAL IMAGING * Akira NABETANI, Hiroyuki KIMURA, Shigeto KABUKI, Atsushi TAKADA, Hidetoshi KUBO, Shotaro KOMURA, Tatsuya SAWANO, Toru TANIMORI, Yoshihiro MATSUOKA, Yoshitaka MIZUMURA, Yuichi HATSUKAWA, Kazuaki TSUKADA, Yasuki NAGAI
7539 部会108 韓国 14 09 Imaging 2 Jun Yeon WON Department of Nuclear Medicine, Seoul National University, Korea, Republic of LINEARIZED TAPPED-DELAY-LINE TIME-TO-DIGITAL CONVERTER FOR TIME-OF-FLIGHT POSITRON EMISSION TOMOGRAPHY * Jae Sung LEE
7540 部会108 韓国 14 09 Imaging 2 Makoto SAKAI Department of School of Medicine, Faculty of Medicine, Gunma University, Japan INFLUENCE OF SCATTERED GAMMA RAYS BY BODY TISSUE ON THE IMAGE OF SEMICONDUCTOR COMPTON CAMERA FOR NUCLEAR MEDICAL USE * Mikiko KIKUCHI, Kota TORIKAI, Kazuo ARAKAWA, Mitsutaka YAMAGUCHI, Yuto NAGAO, Naoki KAWACHI, Shu FUJIMAKI, Tomihiro KAMIYA, Hirokazu ODAKA, Motohide KOKUBUN, Shin’ichiro TAKEDA, Shin WATANABE, Tadayuki TAKAHASHI, Takashi NAKANO
7541 部会108 韓国 14 09 Imaging 2 Su-Jin PARK Department of Department of Radiological Science, Yonsei University, Korea, Republic of COMPARISON OF PERFORMANCE CHARACTERISTICS WITH DIFFERENT COLLIMATORS IN A NEW CZT-BASED SMALL-ANIMAL SPECT * A Ram YU, Yun Young CHOI, Hee-Joung KIM
7542 部会108 韓国 14 09 Imaging 2 Joong Hyun KIM Department of Center for Ionizing Radiation, Korea Research Institute of Standard and Science, Korea, Republic of DESIGN OPTIMIZATION OF SMALL ANIMAL SPECT SYSTEM USING CONTINUOUS LGSO CRYSTAL AND MICRO PARALLEL COLLIMATOR * Mikiko ITO, Seong Jong HONG, Jae Sung LEE
7543 部会108 韓国 14 09 Particle Therapy Akifumi FUKUMURA Department of Reseach Center for Charged Particle Therapy, National Institute of Radiological Sciences, Japan CARBON-ION BEAM DOSIMETRY INTERCOMPARISON IN JAPAN * Nobuyuki KANEMATSU, Toshiyuki SHIRAI, Tatsuaki KANAI, Ken YUSA, Takashi AKAGI, Toshihiro YANOU, Takeshi HIMUKAI, Suoh SAKATA, Katsuhisa NARITA, Nobuhiro TAKASE, Yousuke SASAKI
7544 部会108 韓国 14 09 Particle Therapy Hideaki UEDA Department of Division of Quantum Science and Engineering, Hokkaido University Graduate School of Engineering, Japan PRECISE REPRODUCTION OF PENCIL BEAM PROFILES FOR PROTON BEAM SPOT-SCANNING METHOD BY MONTE-CARLO SIMULATION USING PROTON BEAM-PARAMETERS * Taeko MATSUURA, Yusuke FUJII, Yuka MATSUZAKI, Taisuke TAKAYANAGI, Hirotaka SATO, Michihiro FURUSAKA, Kikuo UMEGAKI, Hiroki SHIRATO
7545 部会108 韓国 14 09 Particle Therapy Seung Hoon YOO Department of Division of Heavy Ion Clinical Research, Korea Institute of Radiological and Medical Science, Korea, Republic of EFFECTIVE GENERATION OF THE SPREAD-OUT-BRAGG PEAK FROM THE LASER ACCELERATED PROTON BEAMS USING A CARBON-PROTON MIXED TARGET. * Ilsung CHO, Sungho CHO, Yongkeun SONG, Won-Gyun JUNG, Dae-Hyun KIM, Dongho SHIN, Se Byeong LEE, Ki-Hong PAE, Sung Yong PARK
7546 部会108 韓国 14 09 Particle Therapy Akihiko MATSUMURA Department of GHMC, Gunma University, Japan EVALUATION OF THE SNOUT POSITION EFFECT ON MONITOR OUTPUT FOR THE CARBON ION THERAPY * Tatsuaki KANAI, Ken YUSA
7547 部会108 韓国 14 09 Particle Therapy Me Young KIM Department of Proton Therapy Center, National Cancer Center, Korea, Republic of REAL-TIME IN SITU PROTON PENCIL BEAM SCANNING MONITOR USING CHERENKOV RADIATION IN OPTICAL FIBERS. * Jae Man SON, Ui-Jung HWANG, Chi Young JEONG, Dong Ho SHIN, Jeong-Hoon PARK, Young Kyung LIM, Se Byeong LEE
7548 部会108 韓国 14 09 Particle Therapy Hiroaki KUMADA Department of Proton Medical Research Center, University of Tsukuba, Japan THE CURRENT STATUS FOR LINAC BASED BNCT PROJECT IN UNIVERSITY OF TSUKUBA * Akira MATSUMURA, Hideyuki SAKURAI, Takeji SAKAE, Kenta TAKADA, Masakazu YOSHIOKA, Hitoshi KOBAYASHI, Hiroshi MATSUMOTO, Toshikazu KURIHARA, Hiroshi NAKASHIMA, Takemi NAKAMURA, Tomei SUGANO, Naoaki IKEDA
7549 部会108 韓国 14 09 Particle Therapy Toshiyuki TOSHITO Department of Department of Proton Therapy Physics, Nagoya Proton Therapy Center, Japan COMMISSIONING OF PROTON BEAM SPOT SCANNING IRRADIATION SYSTEM WITH ENERGY ABSORBER AND APERTURE IN NAGOYA PROTON THERAPY CENTER * Chihiro OMACHI, Keisuke YASUI, Kensuke HAYASHI, Yoshiro KIBE, Hiroyuki SUGAI, Hiroki SHIBATA, Kenichiro TANAKA, Eiki NIKAWA, Kumiko ASAI, Akira SHIMOMURA, Hideto KINOU, Shigeru ISOYAMA, Hiroyuki OGINO, Hiromitsu IWATA, Jun’etsu MIZOE
7550 部会108 韓国 14 09 Particle Therapy Kwanghyun JO Department of Proton Therapy Center, National Cancer Center, Korea, Republic of CURRENT STATUS OF COMMISSIONING PROTON PENCIL BEAM SCANNING IN KNCC * Young Kyung LIM, Dongho SHIN, Jeonghoon PARK, Chiyoung JEONG, Me Young KIM, Jong Hwi JEONG, Eunhee JEANG, Haksoo KIM, Jae-Ik SHIN, Seyjoon PARK, Se Byung LEE
7551 部会108 韓国 14 09 Particle Therapy Naoki MIYAMOTO Department of Department of Medical Physics, Hokkaido University Hospital, Japan DOSIMETRIC EVALUATION OF THE MOVING TARGET IN BEAM GATING IRRADIATION SYSTEM * Masayori ISHIKAWA, Ryusuke SUZUKI, Yuichi HIRATA, Tsuyoshi SASAGAWA, Seiji YAMANAKA, Hiroshi TAMURA, Katsuhisa FUJITA, Tetsuya INOUE, Norio KATO, Hiroki SHIRATO
7552 部会108 韓国 14 09 Radiotherapy Young Eun CHOI Department of Radiation Oncology, Asan Medical Center, Korea, Republic of DIRECT PLAN COMPARISON BETWEEN RAPIDARC AND CYBERKNIFE FOR SPINE STEREOTACTIC BODY RADIATION THERAPY * Jungwon KWAK, Jae Hong PARK, Si Yeol SONG, Eun Kyung CHOI, Seung Do AHN, Byungchul CHO
7553 部会108 韓国 14 09 Radiotherapy Jinsook HA Department of radiation oncology, Gangnam severance hospital, Korea, Republic of ACCURACY OF POSITIONING ERRORS FOR PATIENT SET-UP ON SRS OR SBRT. * Taewon KIM, Mijin JEON, Kwangwoo PARK, Bo Young CHOE, Tae Suk SUH, Hong-Suk JANG
7554 部会108 韓国 14 09 Radiotherapy Jang Bo SHIM Department of Department of Radiation Oncology, College of Medicine, Korea University, Seoul, Korea, Republic of DOSIMETRICAL AND BIOLOGICAL COMPARISON OF MULTI-PLAN TECHNIQUES IN TOMOTHERAPY FOR TONSIL CANCER * Suk LEE, Yuanjie CAO, Kyung Hwan CHANG, Kwang Hyeon KIM, Chul Kee MIN, Woo Chul KIM, Kwang Hwan CHO, Jung Ae LEE, Dae Sik YANG, Won Sup YOON, Young Je PARK, Chul Yong KIM
7555 部会108 韓国 14 09 Radiotherapy Masayori ISHIKAWA Department of Department of Medical Physics and Engineering, Graduate School of Medicine, Hokkaido University, Japan CONSIDERATION OF PASS CRITERIA FOR IMRT CREDENTIALING USING THE GRADIENT METHOD IN MULTI-INSTITUTIONAL CLINICAL TRIALS * Toshiyuki MINEMURA, Hidenobu TACHIBANA, Yasumasa NISHIMURA, Teiji NISHIO, Yuichiro NARITA, Naoki TOHYAMA, Kazuhiko TSUCHIYA, Ryusuke SUZUKI, Satoshi ISHIKURA
7556 部会108 韓国 14 09 Radiotherapy Min-Seok CHO Department of Biomedical Engineering, and Research Institute of Biomedical Engineering, The Catholic University of Korea, College of Medicine, Seoul, Korea, Republic of ANALYSIS OF DOSE ERROR CAUSED BY DOSE RIPPLING PARAMETER IN HELICAL TOMOTHERAPY * Tae-Ho KIM, Seong-Hee KANG, Dong-Su KIM, Kyeong-Hyeon KIM, Tae Suk SUH
7557 部会108 韓国 14 09 Radiotherapy Jong Min PARK Department of Department of Radiation Oncology, Seoul National University Hospital, Korea, Republic of MODULATION INDICES FOR VOLUMETRIC MODULATED ARC THERAPY * So-Yeon PARK, Hyoungnyoun KIM, Hong-Gyun WU, Jin Ho KIM, Joel CARLSON, Sung-Joon YE
7558 部会108 韓国 14 09 Radiotherapy Yuanjie CAO Department of Department of Radiation Oncology, Korea University, Korea, Republic of DOSIMETRICAL AND RADIOBIOLOGICAL COMPARISON OF INTENSITY MODULATED PLANNING TECHNIQUES FOR PROSTATE RADIOTHERAPY: A MULTI-INSTITUTIONAL STUDY * Suk LEE
7559 部会108 韓国 14 09 Radiotherapy Seu-Ran LEE Department of Department of Biomedical Engineering, The Catholic University of Korea, Korea, Republic of THE EVALUATION OF IMPACT FOR DAILY SET UP ERRORS USING PHYSICAL AND RADIOBIOLOGICAL INDICES DEPENDING ON WHOLE BREAST IRRADIATION TECHNIQUES * So-Hyun PARK, Ji-Yeon PARK, Jong-Won KIM, Min-Joo KIM, Tae-Suk SUH
7560 部会108 韓国 14 09 Radiotherapy Hyekyun CHUNG Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Korea, Republic of ASSESSMENT OF GEOMETRIC UNCERTAINTIES IN GATED STEREOTACTIC ABLATIVE BODY RADIOTHERAPY (SABR * Seungryong CHO, Byungchul CHO
7561 部会108 韓国 14 09 Joint Imaging & Therapy Han Rim LEE Department of Nuclear Engineering, Hanyang University, Korea, Republic of PREDICTION OF PERFORMANCE FOR PROTOTYPE GAMMA ELECTRON VERTEX IMAGING (GEVI) SYSTEM BY GEANT4 MONTE CARLO SIMULATION * Jong Hoon PARK, Young-Su KIM, Sung Hun KIM, Won Gyun JUNG, Chan Hyeong KIM
7562 部会108 韓国 14 09 Joint Imaging & Therapy Shintaro TAKEBE Department of Graduate School of Medicine, Master of Biomedical Sciences course, Gunma University, Japan DEFORMED SIMULATION OF A 3D LUNG MODEL BASED ON FEM * Yoshiki KUBOTA, Mutsumi TASHIRO, Tatsuaki KANAI
7563 部会108 韓国 14 09 Joint Imaging & Therapy Dong-Su KIM Department of Biomedical Engineering, Research Institute of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Korea, Republic of LINEAR TOMOSYNTHESIS WITH FLAT-PANEL DETECTOR FOR IMAGE GUIDED RADIATION THERAPY * Tae-Ho KIM, Seong-Hee KANG, Kyeong-Hyeon KIM, Min-Seok CHO, Siyong KIM, Tae Suk SUH
7564 部会108 韓国 14 09 Joint Imaging & Therapy Yuichi SARAYA Department of Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, Japan STUDY OF SPATIAL RESOLUTION AND ELECTRON DENSITY MEASUREMENT FOR PROTON COMPUTED TOMOGRAPHY. * Takuji IZUMIKAWA, Takeo KAWASAKI, Jun GOTO
7565 部会108 韓国 14 09 Joint Imaging & Therapy Su Chul HAN Department of Radiological Cancer Medicine, University of Science and Technology, Korea, Republic of EVALUATION OF VARIOUS DEFORMABLE IMAGE REGISTRATIONS FOR POINT AND VOLUME VARIATIONS * Sang Hyoun CHOI, Seungwoo PARK, Soon Sung LEE, Haijo JUNG, Mi-Sook KIM, Hyung Jun YOO, Young Hoon JI, Chul Young YI, Kum Bae KIM
7566 部会108 韓国 14 09 Joint Imaging & Therapy Hiraku FUSE Department of Department of Radiological Science, Ibaraki prefectural University of Health Science, Japan EFFECT OF METALIC WIRE FOR PROTON BEAM THERAPY * Daisuke KOGUCHI, Koichi YAMANASHI, Miyu IMAIZUMI, Naoki HIRATANI, Yuta KANBE, Masaya INOHIRA, Takeji SAKAE, Tatsuya FUJISAKI
7567 部会108 韓国 14 09 Joint Imaging & Therapy Min-Joo KIM Department of Biomedical Engineering, Research Institute of Biomedical Engineering, The Catholic University of Korea, Korea, Republic of DEVELOPMENT OF PATIENT POSITIONING ERROR COMPENSATION TOOL FOR KOREA HEAVY ION MEDICAL ACCELERATOR CENTER * Woong CHO, Won-Gyun JUNG, Tae-Suk SUH
7568 部会108 韓国 14 09 Joint Imaging & Therapy Seiichi YAMAMOTO Department of Department of Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, Japan IN-BEAM MONITORING OF POSITRON USING HIGH-ENERGY GAMMA CAMERA FOR PROTON THERAPY * Toshiyuki TOSHITO, Masataka KOMORI
7569 部会108 韓国 14 09 Joint Imaging & Therapy Soonki MIN Department of radiation oncology, Asan Medical Center, Korea, Republic of CLINICAL VALIDATION OF AUTO-SEGMENTATION IN PRE-OP PROSTATE, POST-OP PROSTATE AND NOSOPHARYNX CANCER CONTOURING FOR TREATMENT PLANNING * Jungwon KWAK, Youngseok KIM, Sangwook LEE, Byungchul CHO
7570 部会108 韓国 14 09 Dosimetry 2 Sang Koo KANG Department of Radiological & Medical Sciences, Research Center, Dongnam Inst., Korea, Republic of DEVELOPMENT OF INTERGRATED DOSIMETRY CONSOLE FOR IONCHAMBER CALIBRATION * Dong Hyeok JUNG, Man Woo LEE, Yeong-Rok KANG, Heuijin LIM, Jeong Kee KIM
7571 部会108 韓国 14 09 Dosimetry 2 Ryosuke KURIHARA Department of Health Sciences, Kyushu University, Japan RISE-TIME DISTRIBUTIONS OF A POLYETHYLENE-LINED RECOIL PROTON PROPORTIONAL COUNTER FOR FAST NEUTRONS AND GAMMA-RAYS * Akihiro NOHTOMI, Genichiro WAKABAYASHI
7572 部会108 韓国 14 09 Dosimetry 2 Jiwon SUNG Department of Radiation Oncology, Kyung Hee University Hospital at Gangdong, Korea, Republic of SENSING THE RESPIRATORY MOTION BY USING THE GYROSCOPE SENSOR FOR RESPIRATORY GATED RADIOTHERAPY. * Myonggeun YOON, Weon Kuu CHUNG, Dong Wook KIM
7573 部会108 韓国 14 09 Dosimetry 2 Yuhi SUDA Department of Human Health Sciences, Tokyo Metroporitan Univercity, Japan A STUDY ON ENERGY SPECTRUM OF X-RAY BEAM FROM A LINAC USING NAI SCINTILLATION DETECTOR. * Hidetoshi SAITOH
7574 部会108 韓国 14 09 Dosimetry 2 Sang-Won KANG Department of Biomedical Engineering and Research Institute of Biomedical Engineering, College of Medicine, The Catholic University, Korea, Republic of DOSIMETRIC ACCURACY OF ACUROS XB DOSE CALCULATION ALGORITHM ON AN AIR CAVITY FOR FLATTENING FILTER-FREE BEAM * Jin-Beom CHUNG, Jeong-Woo LEE, Ji-Yeon PARK, Tae-Suk SUH
7575 部会108 韓国 14 09 Dosimetry 2 Hiroyuki KINOSHITA Department of Health Sciences, Kyushu University, Japan HIGH SENSITIVE NEUTRON-DETECTION BY A SELF-ACTIVATION METHOD WITH A CSI(TL) SCINTILLATOR AROUND A CLINICAL LINAC * Akihiro NOHTOMI, Soichiro HONDA, Ryousuke KURIHARA, Genichiro WAKABAYASHI, Yasuhiko NAKAMURA, Yoshiyuki UMEZU, Junichi FUKUNAGA
7576 部会108 韓国 14 09 Dosimetry 2 Seong-Hee KANG Department of Biomedical Engineering, Research Institute of Biomedical Engineering, College of Medicine, The Catholic University of Seoul,, Korea, Republic of DOSIMETRIC EFFECT OF FOUR-DIMENSIONAL DOSE ACCUMULATION USING DEFORMABLE IMAGE REGISTRATION IN LIVER STEREOTACTIC BODY RADIOTHERAPY * Tae-Ho KIM, Dong-Su KIM, Min-Seok CHO, Kyeong-Hyeon KIM, Cheon-Keum SEONG, Siyong KIM, Tae Suk SUH
7577 部会108 韓国 14 09 Dosimetry 2 Soichiro HONDA Department of Health Sciences, Kyushu University, Japan EVALUATION OF SELF-SHIELDING EFFECT AND Γ-RAY SUMMATION EFFECT IN A SELF-ACTIVATION METHOD WITH AN NAI(TL) SCINTILLATOR CONTAINING IODINE * Akihiro NOHTOMI, Hiroyuki KINOSHITA, Ryousuke KURIHARA, Genichiro WAKABAYASHI, Yasuhiko NAKAMURA, Yoshiyuki UMEZU, Junichi FUKUNAGA
7578 部会108 韓国 14 09 Dosimetry 2 Heuijin LIM Department of Research Center, Dongnam Institute of Radiological & Medical Sciences, Korea, Republic of CONSTRUCTION AND COMMISSIONING OF THE PROTOTYPE C-BAND LINAC * Dong Hyeok JEONG, Sang Koo KANG, Yeong-Rok KANG, Manwoo LEE, Mujin LEE, Sangjin LEE, Sungjin NOH, Jungyu YI, Kwangmo YANG, Sung Gyun SHIN, Yoon-Kyoo SON, Haeryong YANG, Moohyun CHO, Won NAMKUNG
7579 部会108 韓国 14 09 Simulation Hyun Joon CHOI Department of Radiation Convergence Engineering, Yonsei University, Korea, Republic of FEASIBILITY STUDY FOR IMRT DOSE VALIDATION WITH 4D MONTE CARLO SIMULATION USING GEANT4 * Wook-Geun SHIN, Chul Hee MIN
7580 部会108 韓国 14 09 Simulation Shohei MIZUTANI Department of Pure and Applied Science, University of Tsukuba, Japan APPLICATION OF DOSE KERNEL CALCULATION USING A SIMPLIFIED MONTE CARLO METHOD TO TREATMENT PLANNING FOR IMPT * Yoshihisa TAKADA, Ryosuke KOHNO, Kenji HOTTA, Tetsuo AKIMOTO
7581 部会108 韓国 14 09 Simulation Wook-Geun SHIN Department of Department of Radiation Convergence Engineering and Research Institute of Health Science, Yonsei University, Korea, Republic of A MONTE CARLO STUDY OF THE RELATIONSHIP BETWEEN THE TIME STRUCTURES OF PROMPT GAMMAS AND IN VIVO RADIATION DOSE IN PROTON THERAPY * Jae-Ik SHIN, Jong Hwi JEONG, Se Byeong LEE, Chul Hee MIN
7582 部会108 韓国 14 09 Simulation Kohei SASAKI Department of Faculty of Health Sciences, Hokkaido University of Science, Japan MONTE CARLO SIMULATION FOR THE IMPACT OF REACTIVE OXYGEN SPECIES ON THE RADIATION-INDUCED BYSTANDER EFFECTS * Yuji YOSHII, Yusuke MATSUYA, Hiroyuki DATE
7583 部会108 韓国 14 09 Simulation Jae Beom BAE Department of Radiation Oncology, Asan Medical Center, Korea, Republic of THE SIMULATION OF GEANT4 FOR CONDITION OF OPTIMIZED CARBON ION BEAM NOZZLE IN KOREA HEAVY-ION ACCELERATOR OF THE BIOLOGICAL RESEARCH FACILITY * Byung Cheol CHO, Hyun Tai CHUNG, Young Kyung LIM, Sung Ho PARK, Woo Yoon PARK, Jung Won KWAK
7584 部会108 韓国 14 09 Simulation Sakito FUKUMOTO Department of Graduate School of Health Scirnce, Kumamoto University, Japan DOSE DISTRIBUTION OF AN HDR 192IR BRACHYTHERAPY SOURCE USING MONTE CARLO CODE: PHITS * Fujio ARAKI, Takeshi OHNO, Shintaro HASHIMOTO, Yudai KAI, Takuya FURUTA
7585 部会108 韓国 14 09 Simulation Min Cheol HAN Department of Department of Nuclear Engineering, Hanyang University, Korea, Republic of GENUINE 4D MONTE CARLO DOSE CALCULATION WITH 4D TETRAHEDRAL PATIENT PHANTOM * Yeon Soo YEOM, Chan Hyeong KIM, Seonghoon KIM
7586 部会108 韓国 14 09 Simulation Toshiyuki TOSHIYUKI Department of Department of Proton Therapy Physics, Nagoya Proton Therapy Center, Japan CLINICAL EXPERIENCE OF MONTE CARLO DOSE CALCULATION IN PROTON THERAPY USING SPOT SCANNING IRRADIATION SYSTEM IN NAGOYA PROTON THERAPY CENTER * Chihiro OMACHI, Keisuke YASUI, Kensuke HAYASHI, Yoshiro KIBE, Hiroyuki SUGAI, Kenichiro TANAKA, Eiki NIKAWA, Kumiko ASAI, Akira SHIMOMURA, Hideto KINOU, Shigeru ISOYAMA, Hiroyuki OGINO, Hiromitsu IWATA, Jun’etsu MIZOE
7587 部会108 韓国 14 09 Simulation Do-Kun YOON Department of Department of Biomedical Engineering and Research Institute of Biomedical Engineering, College of Medicine, Catholic University of Korea, Korea, Republic of THEORETICAL VERIFICATION OF PROTON BORON FUSION THERAPY USING MONTE CARLO SIMULATION * Joo-Young JUNG, Tae Suk SUH
7588 部会108 韓国 14 09 Imaging & Joint Taewon LEE Department of Dept. of Nuclear & Quantum Engineering, KAIST, Korea, Republic of LINEAR VERSUS NON-LINEAR MOTION OF THE MULTI-SLIT COLLIMATOR FOR SPARSE SAMPLING CT * Seungryong CHO
7589 部会108 韓国 14 09 Imaging & Joint Minghui TANG Department of Graduate School of Health Sciences, Hokkaido University, Japan DEGENERATION OF BRAIN ARTERIOLAR ELASTICITY OBTAINED FROM SPIN-ECHO SIGNAL FLUCTUATIONS IN DEMENTIA PATIENTS * Toru YAMAMOTO
7590 部会108 韓国 14 09 Imaging & Joint Kyu-Ho SONG Department of Biomedical Engineering, College of Medicine, The Catholic University, Korea, Republic of QUANTIFICATION OF LIVER METABOLITES IN NONALCOHOLIC FATTY LIVER DISEASE (NAFLD) RAT MODEL USING EXTERNAL STANDARD METHOD AT 3T * Do-Wan LEE, Bo-Young CHOE
7591 部会108 韓国 14 09 Imaging & Joint Satoshi OKUMURA Department of Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, Japan DEVELOPMENT OF A NEARLY CIRCULAR-SHAPED PET SYSTEM MADE OF EIGHT BLOCK DETECTORS * Seiichi YAMAMOTO
7592 部会108 韓国 14 09 Imaging & Joint Jeong-Whan SON Department of Nuclear Medicine, Seoul National University, Korea, Republic of TIMING PERFORMANCE OF A TIME-OF-FLIGHT PET SYSTEM BASED ON HIGH QUANTUM EFFICIENCY MULTIANODE PMT AND FPGA-BASED TIME-TO-DIGITAL CONVERTER * Jun Yeon WON, Guen Bae KO, Hyun Suk YOON, Jae Sung LEE
7593 部会108 韓国 14 09 Imaging & Joint Ayaka SHINOHARA Department of Graduate School of Medicine, Gunma University, Japan EVALUATION OF IMAGE AREA DEPENDENCE FOR 2D-3D IMAGE REGISTRATION ACCURACY * Yoshiki KUBOTA, Mutsumi TASHIRO, Satoshi ABE, Saki KOBAYASHI, Takayoshi ISHII, Tatsuaki KANAI
7594 部会108 韓国 14 09 Imaging & Joint Min Sun LEE Department of Interdisciplinary Program in Radiation Applied Life Science, College of Medicine, Seoul National University, Korea, Republic of PROTOTYPE PET SYSTEM WITH A ROTATING PAIR OF DEPTH-OF-INTERACTION ENCODING PET DETECTOR USING DIGITAL SIPM * Kyeong Yun KIM, Guen Bae KO, Jae Sung LEE
7595 部会108 韓国 14 09 Imaging & Joint Masatsugu HARIU Department of Graduate School of Human Health Sciences, Tokyo Metropolitan University, Japan IMPROVEMENT OF IMAGE CONTRAST BY ANALYZING OF COMPTON SCATTERED PHOTONS IMPINGED ON EPID * Atsushi MYOJOYAMA, Hidetoshi SAITOH
7596 部会108 韓国 14 09 Imaging & Joint Min-Young LEE Department of Department of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Korea, Republic of EVALUATION OF THE DOSE ERRORS BY METAL ARTIFACT EFFECTS AND VERIFICATION IN THE DEVELOPED HEAD AND NECK PHANTOM * Jeong-Woo LEE, Ji-Yeon PARK, Hae-Jin PARK, Sang-Won KANG, Tae-Suk SUH
7597 部会108 韓国 14 09 Therapy Tetsuharu MATSUYAMA Department of Department of Energy Sciences, Interdisciplinary Graduate School of Science and Engineering, Tokyo Institue of Technology, Japan MODELING OF RECOMBINATION CHARACTERISTICS IN HEAVY-ION DOSIMETRY WITH A TRACK STRUCTURE MODEL. * Shinji SATO, Yusuke SATAKE, Naruhiro MATSUFUJI
7598 部会108 韓国 14 09 Therapy Kyoungjun YOON Department of Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Korea, Republic of DEVELOPMENT OF 3-DIMENSIONAL DOSIMETRY SYSTEM USING A PHOSPHOR SCREEN WITH CCD DETECTOR IN THE GAMMA KNIFE- PERFEXION™ * Jungwon KWAK, Doheui LEE, Byungchul CHO, Sangwook LEE, Seungdo AHN
7599 部会108 韓国 14 09 Therapy Norifumi MIZUNO Department of Graduate school of Human Health Sciences, Tokyo Metropolitan University, Japan A STUDY OF DEPTH DOSE INCREASE OF SOFT TISSUE SURROUNDING HIGH ATOMIC NUMBER MATERIAL * Haruna ENDO, Shogo HATANAKA, Hidetoshi SAITOH
7600 部会108 韓国 14 09 Therapy Hyunuk JUNG Department of Health Sciences and Technology, SAIHST, Sungkyunkwan University, Korea, Republic of MONTE CARLO SIMULATION OF NOVALIS TX WITH HD 120 MLC AND INTENSITY MODULATED RADIATION THERAPY USING GEANT4 * Kwangzoo CHUNG, Dae-Hyun KIM, Youngyih HAN
7601 部会108 韓国 14 09 Therapy Jihun KWON Department of Graduate School of Health Science, Hokkaido University, Japan MONTE CARLO SIMULATION OF THE ELECTRON PRODUCTION BY PROTON BEAM IRRADIATION TO GOLD PARTICLES * Kenneth SUTHERLAND, Takayuki HASHIMOTO, Hiroyuki DATE
7602 部会108 韓国 14 09 Therapy Jaeman SON Department of Radiation Oncology, National Cancer Center, Korea, Republic of DEVELOPMENT OF NOVEL PROTON DOSIMETRY SYSTEM USING FIBER-OPTIC CERENKOV RADIATION SENSOR * Meyoung KIM, Dongho SHIN, Myonggeun YOON, Sebyeong LEE, Youngkyung LIM, Jeonghoon PARK, Uijung HWANG
7603 部会108 韓国 14 09 Therapy Yusuke SAKURAI Department of Partner Graduate School of Medicine Division of Health Sciences Particle Therapeutics, Osaka University, Japan RIDGE FILTER DESIGN FOR A HELIUM-ION SOBP AND THE EVALUATION OF THE PHYSICAL DOSES AND THE BIOLOGICAL EFFECTS. * Takashi AKAGI, Takuya MAEDA, Nobukazu FUWA, Masao MATSUMOTO, Tomohiro YAMASHITA, Masaki SUGA, Masaaki TAKASHINA, Masahiko KOIZUMI
7604 部会108 韓国 14 09 Therapy Haksoo KIM Department of Proton Therapy Center, National Cancer Center, Korea, Republic of A NOVEL CONFORMITY INDEX BASED ON GEOMETRIC VOLUME DIFFERENCE * Jong Hwi JEONG, Me Young KIM, Chiyoung JEONG, Kwanghyun JO, Jeonghoon PARK, Young Kyung LIM, Dongho SHIN, Se Byung LEE
7605 部会108 韓国 14 09 Therapy Mai FUKAHORI Department of Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, Japan ESTIMATION OF THE RECTAL AND URETHRAL NORMAL TISSUE COMPLICATION PROBABILITY PARAMETERS IN CARBON ION THERAPY FOR PROSTATE CANCER * Naruhiro MATSUFUJI, Takesi HIMUKAI, Nobuyuki KANEMATSU, Hideyuki MIZUNO, Akifumi FUKUMURA, Hiroshi TUJI, Tadashi KAMADA
7606 部会108 韓国 14 09 Imaging & Joint Woo-Jung KIM Department of Department of Biomedical Engineering, The Catholic University of Korea, Korea, Republic of IMPACT ON SMALL FIELD OF VIEW USING MULTI-LAYER PIXEL TYPE COLLIMATION IN COMPUTED TOMOGRAPHY * Do-Kun YOON, Joo-Young JUNG, Bo-Young CHOE
7607 部会108 韓国 14 09 Imaging & Joint Youl-Hun SEOUNG Department of Radiological Science, Cheongju University, Korea, Republic of EVALUATION OF RADIATION DOSE REDUCTION DURING CT SCANS USING OXIDE BISMUTH AND NANO-BARIUM SULFATE SHIELDS
7608 部会108 韓国 14 09 Imaging & Joint Dong-Su KIM Department of Biomedical Engineering, Research Institute of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Korea, Republic of 4D DIGITAL TOMOSYNTHESIS BASED ON ALGEBRAIC IMAGE RECONSTRUCTION AND TOTAL-VARIATION MINIMIZATION FOR THE IMPROVEMENT OF IMAGE QUALITY * Seong-Hee KANG, Tae-Ho KIM, Siyong KIM, Tae Suk SUH
7609 部会108 韓国 14 09 Imaging & Joint Youl-Hun SEOUNG Department of Radiological Science, Cheongju University, Korea, Republic of EVALUATION OF THE SPATIAL RESOLUTION FOR SUPPRESSION DIGITAL PROCESSING OF GRID LINES IN DIGITAL RADIOGRAPHY BY USING MODULATION TRANSFER FUNCTION
7610 部会108 韓国 14 09 Imaging & Joint Young Nam KANG Department of Radiation Oncology, College of Medicine, the Catholic University of Korea, Seoul St.Mary’s Hospital, Korea, Republic of A PRELIMINARY REPORT ON THE DEVELOPMENT OF O-ARM CT LINAC * Shin Wook KIM, Hun Joo SHIN, Jae Choon LEE, Jina KIM, Sang Deok PARK, Ja Choon KOO, Soo Yeol LEE, Sang Hoon JI, Seok Gy JEON, Hong Seok JANG, Yeon Sil KIM, Byung Ock CHOI, Chul Seung KAY
7611 部会108 韓国 14 09 Imaging & Joint Changhwan KIM Department of Nuclear and Quantum Engineering, KAIST, Korea, Republic of DATA CONSISTENCY DRIVEN SCATTER KERNEL OPTIMIZATION FOR CBCT * Miran PARK, Younghun SUNG, Jaehak LEE, Jiyoung CHOI, Seungryong CHO
7612 部会108 韓国 14 09 Imaging & Joint Jonghwan MIN Department of Dept. Nucl. & Quant, KAIST, Korea, Republic of PARALLEL BACKPROJECTION-FILTRATION IMAGE RECONSTRUCTION FROM PARTIAL CONE-BEAM DATA FOR SCATTER CORRECTION * Insu KIM, Seungryong CHO
7613 部会108 韓国 14 09 Imaging & Joint Hosang JEON Department of Radiation Oncology, Pusan National University Yangsan Hospital, Korea, Republic of INDIRECT X-RAY IMAGING RESPONSES OF TWO DIFFERENT SCINTILLATING MATERIALS * Myung Jin CHUNG, Jiho NAM, Ho Kyung KIM
7614 部会108 韓国 14 09 Imaging & Joint Youl-Hun SEOUNG Department of Radiological Science, Cheongju University, Korea, Republic of ANALYSIS OF FACTORS ON AFFECT TO SPATIAL RESOLUTION IN COMPUTED RADIOGRAPHY SYSTEM * Hyeon-Rim LEE, Woo-Ri CHOI, A-Reum HAN, Hye-Rim KIM
7615 部会108 韓国 14 09 Imaging & Joint Sung Hyun LEE Department of Heavy Ion Medicine and Biology, Graduate School of Medicine, Gunma University, Japan THE OPTIMAL ENERGY OF CARBON ION BEAM FOR CARBON ION CT * Akihiko MATSUMURA, Kazuki NAGATAKE, Yosuke KANO, Tatsuaki KANAI
7616 部会108 韓国 14 09 Imaging & Joint Rena LEE Department of Radiation Oncology, School of Medicine, Global Top 5 Research Program, Ewha Womans University, Seoul, Korea, Republic of CHARACTERISTICS OF MINIATURE ELECTRONIC INTRA ORAL DENTAL CT X-RAY SOURCES * Jangyong HUH, Yoonsoe JI, Sukyoung SHIN
7617 部会108 韓国 14 09 Imaging & Joint Jung-Hoon LEE Department of Biomedical Engineering, College of Medicine, The Catholic University, Korea, Republic of QUALITY CONTROL FOR DIFFUSION TENSOR IMAGING USING ACR PHANTOM: COMPARATIVE ANALYSIS WITH 6, 15 AND 32 DIRECTIONS AT 1.5T AND 3.0T MRI SYSTEMS * Sang-Young KIM, Do-Wan LEE, Kyu-Ho SONG, Bo-Young CHOE
7618 部会108 韓国 14 09 Imaging & Joint Kyu-Ho SONG Department of Biomedical Engineering, College of Medicine, The Catholic University, Korea, Republic of ENHANCED QUALITY ASSURANCE TESTING OF MAGNETIC RESONANCE IMAGING AND SPECTROSCOPY USING FUSED PHANTOM * Do-Wan LEE, Jin-Young JUNG, Jung-Hoon LEE, Bo-Young CHOE
7619 部会108 韓国 14 09 Imaging & Joint Jinho JEONG Department of General Surgery, Myongji hospital, Korea, Republic of MR IMAGES OF MOUSE BRAIN USING CLINICAL 3T MR SCANNER AND 4CH-MOUSE COIL * Soo Mee LIM, Eun Mi PARK
7620 部会108 韓国 14 09 Imaging & Joint Heesoon SHEEN Department of MICT team, GE Healthcare Korea, Korea, Republic of GATE MONTE CARLO SIMULATION OF GE DISCOVERY 600 * Youngyih HAN
7621 部会108 韓国 14 09 Imaging & Joint Sang-Keun WOO Department of Molecular Imaging Research Center, Korea Institute of Radiological and Medical Sciences, Korea, Republic of EVALUATION OF INFORMATION BASED PET AND MRI IMAGE REGISTRATION ALGORITHM * Han Kyeol SONG, Jeong A LEE, Sang Moo LIM, Kyeong Min KIM
7622 部会108 韓国 14 09 Imaging & Joint Seunghan HONG Department of School of Biomedical Engineering, BK21 Plus Research Institute of Biomedical Engineering, Konkuk University, Korea, Republic of FEASIBILITY STUDY ON DEVELOPMENT OF A FIBER-OPTIC GAMMA IMAGING DETECTOR * Wook Jae YOO, Sang Hun SHIN, Hyeok In SIM, Seon Geun KIM, Hyesu JEON, Jae Seok JANG, Jae Seok KIM, Guwon KWON, Kyung Won JANG, Bongsoo LEE
7623 部会108 韓国 14 09 Imaging & Joint Taewoong LEE Department of Bio-convergence Engineering, Korea University, Korea, Republic of EVALUATION OF MULTIPLE SCATTERING COMPTON CAMERA IN 6-MV PHOTON THERAPY AND OPTIMIZED MATERIALS * Wonho LEE
7624 部会108 韓国 14 09 Imaging & Joint Sungho CHO Department of Division of heavy-ion clinical researches, Korea Institute of Radiological and Medical Sciences, Korea, Republic of EVALUATION OF INTENSITY BASED 2D-3D IMAGE REGISTRATION FOR PATIENT POSITIONING IN RADIOTHERAPY * Yongkeun SONG, Ilsung CHO, Seunghoon YOO, Wongyun JUNG
7625 部会108 韓国 14 09 Dosimetry Soah PARK Department of Department of Radiation Oncology, Hallym University College of Medicine, Korea, Republic of ABSORPTION SPECTRUM OF GAFCHROMIC® EBT2 FILM WITH ANGULAR ROTATION * Kwang-Ho CHEONG, Taejin HWANG, Jai-Woong YOON, Taejin HAN, Haeyoung KIM, Me-Yeon LEE, Kyoungju KIM, Hoonsik BAE, Seung Jae OH, Yong-Min HUH, Jin-Suck SUH, Sei-Kwon KANG
7626 部会108 韓国 14 09 Dosimetry Yusuke KOBA Department of Medical Exposure Research Project, National Institute of Radiological Sciences, Japan THE THERMOLUMINESCENCE EFFICIENCY OF ALUMINA-BASED CERAMIC PLATE DOSIMETER TO CARBON-ION BEAMS * Kiyomitsu SHINSHO, Chie KOYAMA, Wakabayashi GENICHIRO, Shigekazu FUKUDA
7627 部会108 韓国 14 09 Dosimetry Jihye KOO Department of Radiation Oncology, Kyung Hee University Hospital at Gangdong, Korea, Republic of RADIOTHERAPY INCIDENTS ANALYSIS BASED ON ROSIS : TENDENCY AND FREQUENCY * Myonggeun YOON, Wonkyu JUNG, Dongwook KIM
7628 部会108 韓国 14 09 Dosimetry In Jung KIM Department of Center for Ionizing Radiation, Korea Research Institute of Standards and Science, Korea, Republic of THERMAL ANALYSIS OF A GRAPHITE CALORIMETER FOR THE MEASUREMENT OF MEGAVOLTAGE PHOTON BEAM ABSORBED DOSE * Byoung Chul KIM, Joong Hyun KIM, Chul-Young YI
7629 部会108 韓国 14 09 Dosimetry Seheon KIM Department of Department of Biomedical Engineering, The Catholic University of Korea, Korea, Republic of THE COMPARISON OF ABSORBED DOSE IN GKS PLANNING BASED ON THE DIFFERENT DOSE ALGORITHMS * Taeseok SEO
7630 部会108 韓国 14 09 Dosimetry Dong Joo RHEE Department of Research Center, Dongnam Institute of Radiological and Medical Sciences, Korea, Republic of EFFECTS OF THE DIFFERENCE IN TUBE VOLTAGE OF THE CT SCANNER ON DOSE CALCULATION * Sung-Woo KIM, Young Min MOON, Jung Ki KIM, Dong Hyeok JUNG
7631 部会108 韓国 14 09 Dosimetry Sohail SABIR Department of Nuclear & Quantum Engineering, KAIST BRIDGING THE GAP IN NUCLEAR EMERGENCY RESPONSE AND PREPAREDNESS: A REVIEW ON IN VIVO EPR RETROSPECTIVE DOSIMETRY DEVELOPMENT * Seungryong CHO
7632 部会108 韓国 14 09 Dosimetry Jungyu YI Department of Research Center, Dongnam Inst. of Radiological & Medical Sciences, Korea, Republic of DESIGN AND PROTOTYPE TEST OF ACCELERATING CAVITIES FOR C-BAND ELECTRON LINAC * Mawoo LEE, Dong Hyeok JEONG, Sang Koo KANG, Yeong-Rok KANG, Mujin LEE, Sangjin LEE, Heuijin LIM, Sungjin NOH, Kwangmo YANG, Sung Gyun SHIN, Moohyun CHO, Haeryong YANG, Won NAMKUNG
7633 部会108 韓国 14 09 Dosimetry Se An OH Department of Radiation Oncology, Yeungnam University Medical Center, Korea, Republic of BEAM CHARACTERISTICS IN THE SMALL FIELD OF THE NOVALIS TX WITH GAFCHROMIC EBT2 FILM AND EDGE DETECTOR * Sung Kyu KIM, Ji Woon YEA, Sang Woon KIM
7634 部会108 韓国 14 09 Dosimetry Seonghoon JEONG Department of Radiation Oncology, Kyung Hee University Hospital at Gang-Dong, Korea, Republic of PROPERTY OF INTRAOPERATIVE RADIOTHERAPY BEAM USING ELECTRON-GUIDING APPLICATORS AND SECONDARY CANCER RISK NEAR ORAL CAVITY * Weon Kuu CHUNG, Dong Wook KIM, Jiwon SUNG, Jihye KOO, Myeonggeun YOON
7635 部会108 韓国 14 09 Dosimetry Sung-Woo KIM Department of Research center, Dongnam Institute of Radiological & Medical sciences, Korea, Republic of MEASUREMENT OF ELECTRON BEAM OUTPUT FROM PROTOTYPE RESEARCH LINAC * Dong Joo RHEE, Heuijin LIM, Manwoo LEE, Sang Koo KANG, Dong Won KWAK, Young Min MOON, Jung Ki KIM, Tae Ik RO, Dong Hyeok JEONG
7636 部会108 韓国 14 09 Dosimetry Tae-Ho KIM Department of Department of Biomedical Engineering, Research Institute of Biomedical Engineering, College of Medicine, The Catholic University, Korea, Republic of FEASIBILITY STUDY OF PATIENT MOTION MONITORING USING TACTILE ARRAY SENSOR * Seong-Hee KANG, Dong-Su KIM, Min-Seok CHO, Kyeong-Hyeon KIM, Siyong KIM, Tae Suk SUH
7637 部会108 韓国 14 09 Dosimetry Soonhyouk LEE Department of Medical Research Institute, Ewha Womans University, Korea, Republic of RESEARCH OF SCINTILLATOR FOR THE MULTICHANNEL GAS ELECTRON MULTIPLIER DETECTOR * Jae Hoon JUNG, Rena LEE
7638 部会108 韓国 14 09 Dosimetry Jiwon SUNG Department of Radiation Oncology, Kyung Hee University Hospital at Gangdong, Korea, Republic of DOSIMETRIC CHARACTERISTICS OF RADIO-PHOTOLUMINESCENCE GLASS DOSIMETER (RPLGD) WITH ACCUMULATED DOSES * Jaeman SON, Myonggeun YOON, Weon Kuu CHUNG, Dong Wook KIM
7639 部会108 韓国 14 09 Dosimetry Dong Hyeok JEONG Department of Research center, Medical Radiation Physics Laboratory, Dongnam Inst. of Radiological & Medical Sciences, Korea, Republic of STUDY ON THE ELECTROMETER CONNECTION FOR THE IONIZATION CURRENT MEASUREMENT USING KEITHLEY-6517B HIGH RESISTANCE METER * Dong Joo RHEE, Heuijin LIM, Yeong-Rok KANG, Manwoo LEE, Jung Kee KIM
7640 部会108 韓国 14 09 Dosimetry Akifumi FUKUMURA Department of Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, Japan DOSIMETRY INTERCOMPARISON FOR HIGH ENERGY THERAPEUTIC X-RAYS BETWEEN PAKISTAN, VIETNAM, KAZAKHSTAN, THAILAND AND JAPAN IN THE FRAMEWORK OF FORUM FOR NUCLEAR COOPERATION IN ASIA (FNCA) * Shigekazu FUKUDA, Hideyuki MIZUNO, Mai FUKAHORI, Kumiko KARASAWA
7641 部会108 韓国 14 09 Dosimetry Kyo Chul SHIN Department of Radiation Oncology, Dankook University Hospital,Cheonan, Korea, Republic of DESIGN OF AIR-KERMA CALIBRATION DEVICE FOR AN ENCAPSULATED IR-192 SEED * Sang Gyu CHOI, Ki Hwan KIM, Jhin Kee KIM, Jung Ki KIM, Dong Hyeok JEONG
7642 部会108 韓国 14 09 Dosimetry So Hyun AHN Department of Department of Radiation Oncology, Gachon University Gil Hospital, Korea, Republic of APPLICATION OF EBT3 FILM AND MONTE CARLO EVALUATION FOR VERY SMALL FIELD DOSIMETRY * Jin Ho CHOI, Kyu Chan LEE, Seok Ho LEE, Seung Heon LEE, Kihoon SUNG
7643 部会108 韓国 14 09 Dosimetry Kyung Hwan CHANG Department of Radiation Oncology, College of Medicine, Korea University, Korea, Republic of DEVELOPMENT OF A RAPID, PATIENT-BASED, THREE-DIMENSIONAL DOSE SCANNER (P3DS) FOR DOSE GUIDED ADAPTIVE RADIATION THERAPY * Suk LEE, Yuanjie CAO, Jang Bo SHIM, Kwang Hyeon KIM, Sam Ju CHO, Hong JEONG, Suk Woo CHOI, Jin Soo KO, Nam Kwon LEE, Won Sup YOON, Young Je PARK, Dae Sik YANG, Chul Yong KIM
7644 部会108 韓国 14 09 Dosimetry Sang Hyoun CHOI Department of Research Center for Radiotherapy, Korea Institute of Radiological and Medical Science, Korea, Republic of DETERMINATION OF ION RECOMBINATION CORRECTION FACTORS FOR LIQUID IONIZATION CHAMBER IN MEGAVOLTAGE PHOTON BEAMS * Seoung Hoon KIM, Kum Bae KIM, Young Hoon JI, Hyun Do HUH, Yongkeun SONG, Dong-Wook PARK, Mi-Sook KIM, Hyung Jun YOO, Chan Hyeong KIM
7645 部会108 韓国 14 09 Dosimetry Dong-Wook PARK Department of Radiation Oncology, Ilsan Paik Hospital, Korea, Republic of THE EVALUATION OF ENERGY DEPENDENCY OF RPGLD IN MV PHOTON BEAM, * Sang Hyoun CHOI, Jai-Ki LEE
7646 部会108 韓国 14 09 Dosimetry Jeong-Woo LEE Department of Radiation Oncology, Konkuk University Medical Center, Korea, Republic of VERIFICATION OF CARDIAC PACEMAKER DOSES IN INTENSITY MODULATED RADIATION THERAPY: IN-VIVO DOSIMETRY FOR EFFECTIVE DOSE DELIVERY AND REDUCTION STRATEGY * Semie HONG, Jin-Beom CHUNG
7647 部会108 韓国 14 09 Dosimetry Sukyoung SHIN Medical Research Institute, Ewha Womans University, Seoul, Korea, Republic of SPECTRUM ANALYSIS FOR THE EFFICIENCY OF GAS ELECTRON MULTIPLIER DETECTOR * Jae Hoon JUNG, Soonhyouk LEE
7648 部会108 韓国 14 09 Dosimetry Sukyoung SHIN Department of Medical Science, Ewha Womans University, Seoul, Korea, Republic of THE INFLUENCE OF E- BEAM IRRADIATION ON PROPERTIES OF MEDICAL GRADE POLYURETHANE
7649 部会108 韓国 14 09 Monte Carlo Do-Kun YOON Department of 1Department of Biomedical Engineering and Research Institute of Biomedical Engineering, College of Medicine, Catholic University of Korea, Korea, Republic of MONTE CARLO DESIGN AND SIMULATION OF A GRID−TYPE MULTI−LAYER PIXEL COLLIMATOR FOR RADIOTHERAPY: FEASIBILITY STUDY * Joo-Young JUNG, Tae Suk SUH
7650 部会108 韓国 14 09 Monte Carlo Yongkeun SONG Department of Division of heavy ion clinical research, Korea Institute of Radiological and Medical Sciences, Korea, Republic of STUDY ON THE DESIGN OF RIDGE FILTER USING MONTE CARLO SIMULATION * Sungho CHO, Ilsung CHO, Seunghoon YOO, Wongyun JUNG
7651 部会108 韓国 14 09 Monte Carlo Ryo OGAWARA Department of Medical Physics and Engineering, Hokkaido University graduate school of medicine, Japan SIMULATION STUDY ON EFFECT OF OUT-OF-FIELD RADIATION FOR MOLECULAR-IMAGING-BASED TUMOR TRACKING RADIOTHERAPY WITH THE PARALLEL-PLANE PET SYSTEM * Mitsuhiro YOSHIDA, Naoyuki UKON, Hiroki SHIRATO, Masayori ISHIKAWA
7652 部会108 韓国 14 09 Monte Carlo Byung Yong KIM Department of Department of Physics, College of Science, Yeungnam University, Korea, Republic of 6MV PHOTON BEAM MODELING FOR VARIAN CLINAC IX USING GEANT4 VIRTUAL GEOMETRY * Hyung Dong KIM, Su Ho MOON, Jeong Ku KANG, Sung Kyu KIM
7653 部会108 韓国 14 09 Monte Carlo Kyeong-Hyeon KIM Department of Biomedical Engineering, College of Medicine, the Catholic University of Korea, Korea, Republic of INVESTIGATION TO ACCURACY OF 3D GAMMA EVALUATION IN IMRT QA: MONTE CARLO SIMULATION STUDY * Dong-Su KIM, Tae-Ho KIM, Seong-Hee KANG, Min-Seok CHO, Tae Suk SUH
7654 部会108 韓国 14 09 Monte Carlo Jae-Ik SHIN Department of Proton Therapy Center, National Cancer Center, Korea, Republic of THE VALIDATION OF THE DEVELOPED MONTE CARLO SIMULATION PLATFORM FOR DESIGNING THE NOZZLE OF PARTICLE THERAPY BEAM * Seyjoon PARK, Haksoo KIM, Dongho SHIN, Young Kyung LIM, Jeonghoon PARK, Se Byeong LEE, Sung Yong PARK, Jungwook SHIN, Sebastien INCERTI
7655 部会108 韓国 14 09 Monte Carlo Tsukasa ASO Department of Electronics and Computer Engineering, National Institute of Technology, Toyama College, Japan SOFTWARE DESIGN FOR EXTENDING GEANT4 BASED PARTICLE THERAPY SYSTEM SIMULATION FRAMEWORK TO MEDICAL IMAGING APPLICATIONS * Keiichiro MATSUSHITA, Teiji NISHIO, Shigeto KABUKI
7656 部会108 韓国 14 09 Monte Carlo Dae-Hyun KIM Department of Department of Radiation Oncology, Samsung Medical Center, Korea, Republic of IMPROVEMENT OF CALCULATING EFFICIENCY FOR PROTON THERAPY NOZZLE USING GEANT4 MULTI-THREADING * Youngyih HAN, Sung-Hwan AHN, Kwangzoo CHUNG, Jing Sung KIM, Sungkoo CHO, Eunhyuk SHIN, Jungsuk SHIN, Doo Ho CHOI, Tae-Suk SUH
7657 部会108 韓国 14 09 Monte Carlo Sang Koo KANG Department of Research Center, Dongnam Institute of Radiological and Medical Sciences, Korea, Republic of GEANT4 SIMULATION ON THE DOSE DISTRIBUTIONS IN WATER FOR A PROTOTYPE HIGH ENERGY X-RAY AND ELECTRON BEAM GENERATOR * Dong Hyeok JEONG
7658 部会108 韓国 14 09 Monte Carlo Jae Seok KIM Department of School of Biomedical Engineering, BK21 Plus Research Institute of Biomedical Engineering, Konkuk University, Korea, Republic of CALCULATION OF ELECTRON FLUXES IN VARIOUS CERENKOV RADIATORS USING MCNPX CODE * Bongsoo LEE, Kyoung Won JANG, Sang Hun SHIN, Hyeok In SIM, Seon Geun KIM, Seunghan HONG, Hyesu JEON, Jae Seok JANG, Guweon KWON, Wook Jae YOO
7659 部会108 韓国 14 09 Monte Carlo Woo Sang AHN Department of Radiation Oncology, Gangneung Asan Hospital, Gangneung, Korea, Republic of DOSIMETRIC CHARACTERISTICS OF A NEW ELECTRONIC BRACHYTHERAPY SOURCE USING MONTE CARLO SIMULATIONS * Byung Chul CHO, Sung Ho PARK, Wonsik CHOI, Seong Soo SHIN, Hyun Jin KIM, Sung Oh CHO
7660 部会108 韓国 14 09 Monte Carlo Yoonjin OH Department of Radiological Science, Dongseo University, Korea, Republic of STUDY ON DESIGN OF X-RAY PROTECTIVE DEVICE FOR EYES IN DENTAL PANORAMIC RADIOGRAPHY SYSTEM BY USING MONTE CARLO SIMULATION (MCNPX CODE) * Samyol LEE, Girang HONG
7661 部会108 韓国 14 09 Monte Carlo Jeong Ok LEE Department of Radiation, Wonkwong Health Science University, Korea, Republic of VERIFICATION OF GEANT4 SIMULATION RESULTS USING THE RADIOCHROMIC FILM DOSIMETRY * Jeong Gu KANG, Bu Gil KIM, Jhin Kee KIM, Hyeong Cheol KWON, Jung Soo KIM, Dong Hyeok JEONG
7662 部会108 韓国 14 09 Monte Carlo Jeong Ok LEE Department of Radiation, Wonkwong Health Science University, Korea, Republic of STUDY ON THE GEANT4 CODE APPLICATIONS TO THE DOSE CALCULATION USING IMAGING DATA * Jeong Gu KANG, Bu Gil KIM, Jhin Kee KIM, Kyo Chul SHIN, Ki Hwan KIM, Young Kee OH, Jung Ki KIM, Dong Hyeok JEONG
7663 部会108 韓国 14 09 Particle Therapy Masayori ISHIKAWA Department of Department of Medical Physics and Engineering, Graduate School of Medicine, Hokkaido University, Japan CLINICAL APPLICATION OF SCINTILLATOR WITH OPTICAL FIBER DETECTOR AS A REAL-TIME THERMAL NEUTRON MONITOR DURING BORON NEUTRON CAPTURE THERAPY * Koji ONO, Akira MATSUMURA, Tetsuya YAMAMOTO, Junichi HIRATSUKA, Shinichi MIYATAKE, Itsuro KATO, Yoshinori SAKURAI, Hiroaki KUMADA
7664 部会108 韓国 14 09 Particle Therapy Shigekazu FUKUDA Department of Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, Japan DEVELOPMENT OF 3D MEASUREMENT DEVICE DEDICATED FOR RANGE-COMPENSATOR QA 3 * Eriko URAKABE, Kiyohiro YAMADA, Shinichi MINOHARA
7665 部会108 韓国 14 09 Particle Therapy Manabu MIZOTA Department of Accelerator and Medical Physics, National Institute of Radiological Sciences, Japan A LAYER-STACKING IRRADIATION FOR QUALITY ASSURANCE IN BROAD BEAM THERAPY AT HIMAC
7666 部会108 韓国 14 09 Particle Therapy Takaomi HARADA Department of Radiological and Medical Laboratory Sciences, Nagoya University Graduate School, Japan DETERMINING THE OPTIMAL INTERVAL OF ADJACENT FIELDS WITH A MULTI-PATCH IRRADIATION IN PROTON THERAPY * Keisuke YASUI, Chihiro OMACHI, Toshiyuki TOSHITO, Tomoki KITAGAWA, Eri SEKIHARA, Ryota SHIMOKOMAKI, Hiroshi OGUCHI, Masataka KOMORI
7667 部会108 韓国 14 09 Particle Therapy Sei-Kwon KANG Department of Radiation Oncology, College of Medicine, Hallym University, Korea, Republic of STABILITY CHECK OF THE REFERENCE ION CHAMBER USED FOR THE ACCELERATOR OUTPUT CALIBRATION * Jai-Woong YOON, Soah PARK, Taejin HWANG, Kwang-Ho CHEONG, Tae Jin HAN, Haeyoung KIM, Me-Yeon LEE, Kyoung Ju KIM, Hoonsik BAE
7668 部会108 韓国 14 09 Particle Therapy Soorim HAN Department of Particle Physics Group, Chiba University Graduate School of Science, Japan CALIBRATION METHOD FOR PMMA MULTI-LAYER IONIZATION CHAMBER FOR HEAVY ION RADIOTHERAPY * Soma IWATA, Shigekazu FUKUDA
7669 部会108 韓国 14 09 Particle Therapy Joo-Young JUNG Department of Department of Biomedical Engineering and Research Institute of Biomedical Engineering, College of Medicine, Catholic University of Korea, Korea, Republic of SINGLE PHOTON IMAGE FROM PET WITH INSERTABLE COLLIMATOR FOR BNCT * Do-Kun YOON, Key Jo HONG, Hongseok JANG, Tae Suk SUH
7670 部会108 韓国 14 09 Particle Therapy Mari SHINOZAKI Department of physics, Toho University, Japan RANGE SHIFTER DEPENDENCE OF THE FIELD-SIZE EFFECT IN THE DEPTH DOSE DISTRIBUTION OF CARBON IRRADIATION * Manabu MIZOTA
7671 部会108 韓国 14 09 Particle Therapy Takeji SAKAE Department of Proton Medical Research Center, University of Tsukuba, Japan PERFORMANCE OF GPU FOR A NOVEL CALCULATION METHOD OF PROTON DOSE DISTRIBUTION. * Hiroaki KUMADA, Kiyoshi YASUOKA, Toshiyuki TERUNUMA
7672 部会108 韓国 14 09 Particle Therapy Kouhei YOKOKAWA Department of Graduate School of Engineering, Hokkaido University, Japan A MODELING STUDY OF THE USE OF SOBP-FORMING MINI-RIDGE-FILTERS IN PROTON-BEAM SPOT SCANNING METHOD * Michihiro FURUSAKA, Hideaki UEDA
7673 部会108 韓国 14 09 Particle Therapy Seung Hoon YOO Department of Division of Heavy Ion Clinical Research, Korea Institute of Radiological and Medical Science, Korea, Republic of SIMULATION STUDY OF DOSE ENHANCEMENT IN A CELL DUE TO NEARBY CARBON AND OXYGEN IN PARTICLE RADIOTHERAPY * Ilsung CHO, Sungho CHO, Yongkeun SONG, Won-Gyun JUNG, Dongho SHIN, Se Byeong LEE, Jae Il SHIN, Myonggeun YOON, Sebastian INCERTI, Moshi GESO, Anatoly B. ROSENFELD
7674 部会108 韓国 14 09 Particle Therapy Sungho CHO Department of Division of heavy-ion clinical researches, Korea Institute of Radiological and Medical Sciences, Korea, Republic of ANALYSIS OF NEUTRON PRODUCTION AND INDUCED RADIOACTIVITY IN PASSIVELY SCATTERED ION RADIOTHERAPY * Youngkeun SONG, Ilsung CHO, Seunghoon YOO, Wongyun JUNG
7675 部会108 韓国 14 09 Particle Therapy Shu MIKAMI Department of Physics, Toho university, Japan APPLICABILITY OF DOSE-MEAN LET AS AN INDEX OF BIOLOGICAL EFFECTIVENESS OF THERAPEUTIC CARBON-ION BEAMS * Masao SUZUKI, Naruhiro MATSUFUJI
7676 部会108 韓国 14 09 Particle Therapy Eun Ho KIM Department of KIRAMS, Division of Heavy Ion Clinical Research, Korea, Republic of RADIOSENSITIZATION OF METFORMIN TO C-ION BEAM RADIATION IN HCC * Mi-Sook KIM, Yoshitaka MATSUMOTO, Yoshiya FURUSAWA, Won-Gyun JUNG
7677 部会108 韓国 14 09 Particle Therapy Kazuki NAGATAKE Department of Graduate School of Medicine, Master of Biomedical Sciences course, Gunma University, Japan DEVELOPMENT OF A NEW TREATMENT METHOD USING CARBON BEAMS “CARBON KNIFE” * Tatsuaki KANAI, Mutsumi TASHIRO, Akihiko MATSUMURA, Yoshiki KUBOTA, Hikaru SOUDA, Yoshiyuki KONISHI, Motohiro HAYASHI, Yosuke KANO, Masato TSUNEDA
7678 部会108 韓国 14 09 Particle Therapy Seung Hoon YOO Department of Division of Heavy Ion Clinical Research, Korea Institute of Radiological and Medical Science, Korea, Republic of VERIFICATION OF THE DOSE UNCERTAINTY FOR TISSUE AND AIR IN PROTON IRRADIATION * Ilsung CHO, Sungho CHO, Yongkeun SONG, Won-Gyun JUNG, Dongho SHIN, Se Byeong LEE, Jae Man SON, Myonggeun YOON
7679 部会108 韓国 14 09 Particle Therapy Ilsung CHO Department of Division of Heavy Ion Clinical Research, Korea Institute of Radiological and Medical Science, Korea, Republic of SIMULATION STUDY OF MICRODOSIMETRY SPECTRA FOR BIOPHYSICAL MODELING OF CARBON ION THERAPY * Won-Gyun JUNG, Seunghoon YOO, Sungho CHO, Eun Ho KIM, Yongkeun SONG
7680 部会108 韓国 14 09 Particle Therapy Takayoshi ISHII Department of Div. of Radiology, Gunma University Hospital, Japan PRELIMINARY STUDY FOR CALCULATION METHOD OF POSITRON-EMITTING RADIONUCLIDE AFTER CARBON ION THERAPY * Kazuhisa TSUDA, Yusuke ITABASHI, Ken YUSA, Takayuki SUTOU, Tatsuya OHNO, Takashi NAKANO, Tatsuaki KANAI
7681 部会108 韓国 14 09 Particle Therapy Joo-Young JUNG Department of Department of Biomedical Engineering, The Catholic University of Korea, College of Medicine, Korea, Republic of A PRELIMINARY STUDY ON IMAGING OF THERAPY REGION FROM BORON NEUTRON CAPTURE THERAPY * Do-Kun YOON, Tae Suk SUH
7682 部会108 韓国 14 09 Particle Therapy Junichi DOI Department of Pure and applied science, University of Tsukuba, Japan A STUDY OF BI-MATERIAL RANGE COMPENSATOR FOR CARBON-ION THERAPY * Yoshihisa TAKADA, Shohei MIZUTANI
7683 部会108 韓国 14 09 Particle Therapy Kota MIZUSHIMA Department of Accelerator and Medical Physics, National Institute of Radiological Sciences, Japan UPGRADE OF SYNCHROTRON OPERATION FOR SCANNED CARBON-ION THERAPY AT NIRS-HIMAC * Yoshiyuki IWATA, Takuji FURUKAWA, Shinji SATO, Toshiyuki SHIRAI, Koji NODA
7684 部会108 韓国 14 09 Particle Therapy Mitsutaka KANAZAWA Department of Ion Beam Therapy Center, SAGA-HIMAT Foundation, Japan PRESENT STATUS OF SAGA-HIMAT * Masahiro ENDO, Takeshi HIMUKAI, Yoshikazu TSUNASHIMA, Hiroshi SATO, Eishu SHINKAI, Sho KUDO, Yoshiyuki SHIOYAMA, Makoto KITAMURA, Tadahide TOTOKI
7685 部会108 韓国 14 09 Particle Therapy Takahiro YAMADA Department of Department of Radiology, Hokkaido University Hospital, Japan VALIDATION OF TREATMENT PLANNING SYSTEM OF A SPOT-SCANNING PROTON THERAPY AT HOKKAIDO UNIVERSITY * Taeko MATSUURA, Seishin TAKAO, Naoki MIYAMOTO, Chie TORAMATSU, Shinichi SHIMIZU, Shusuke HIRAYAMA, Hideaki NIHONGI, Masahiro HOSAKA, Yoshihiko NAGAMINE, Kikuo UMEGAKI, Hiroki SHIRATO
7686 部会108 韓国 14 09 Particle Therapy Satoshi KAMIZAWA Department of Proton Medical Research Center, University of Tsukuba, Japan DOSE DISTRIBUTION IN PROTON THERAPY USING PATCH-FIELD TECHNIQUE WITH GATED IRRADIATION FOR ESOPHAGEAL CANCER * Hideyuki TAKEI, Toshiyuki TERUNUMA, Masaya ISHIDA, Tomonori ISOBE, Hitoshi ISHIKAWA, Hideyuki SAKURAI, Takeji SAKAE
7687 部会108 韓国 14 09 Particle Therapy Hiroki TANAKA Department of Radiation Life Science and Radiation Medical Science, Kyoto University Research Reactor Institute, Japan DEVELOPMENT OF A REAL-TIME DOSIMETER FOR BORON NEUTRON CAPTURE THERAPY * Yoshinori SAKURAI, Minoru SUZUKI, Shin-Ichiro MASUNAGA, Takushi TAKATA, Nozomi FUJIMOTO, Kazuya TAKI, Akira MARUHASHI, Koji ONO
7688 部会108 韓国 14 09 Particle Therapy Kwangzoo CHUNG Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Korea, Republic of THE PROTON THERAPY NOZZLES AT SAMSUNG MEDICAL CENTER: A MONTE CARLO SIMULATION STUDY USING TOPAS * Sunghwan AHN, Youngyih HAN
7689 部会108 韓国 14 09 Particle Therapy Kwanghyun JO Department of Proton Therapy Center, National Cancer Center, Korea, Republic of A METHOD FOR VERIFYING SETUP POSITION OF CRANIOSPINAL IRRADIATION BY PHOTON-PROTON COMBINED TREATMENT * Se Byung LEE, Dongho SHIN, Jeonghoon PARK, Chiyoung JEONG, Me Young KIM, Jong Hwi JEONG, Eunhee JEANG, Haksoo KIM, Young Kyung LIM
7690 部会108 韓国 14 09 Particle Therapy Jin Sung KIM Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea, Republic of FEASIBILITY STUDY OF NEUTRON DOSE FOR REAL TIME IMAGE GUIDED PROTON THERAPY * Jung Suk SHIN, Kwangzoo CHUNG, Eunhyuk SHIN, Youngyih HAN
7691 部会108 韓国 14 09 Particle Therapy Shinichiro MORI National Institute of Radiological Sciences, Japan IMAGE-GUIDED CARBON-ION SCANNING BEAM TREATMENT FOR MOVING TARGET
7692 部会108 韓国 14 09 Radiotherapy Hiroki INATA Department of Graduate School of Health Sciences, Kumamoto University, Japan ANALYSIS FOR THE PRESSURE LEVEL AND THE ACCURACY OF THE IMMOBILIZATION USING THE HEAD MASK SYSTEM: PHANTOM STUDY * Fujio ARAKI, Yuta KURIBAYASHI, Noritaka SODEOKA, Shigeki NAKAYAMA, Yasushi HAMAMOTO, Hiroto TAKEUCHI, Suetoshi MURAYAMA, Osamu NISHIZAKI
7693 部会108 韓国 14 09 Radiotherapy Jung-In KIM Department of Radiation Oncology, Seoul National University Hospital, Korea, Republic of DOSIMETRIC EVALUATION OF HEAD AND NECK PATIENT USING A COMMERCIAL ORTHOPEDIC METAL ARTIFACT REDUCTION TOOL IN RADIATION THERAPY * Hyuckjun KWON, Kyung Su KIM, Young Mi CHUN, Hong-Gyun WU, Sung-Joon YE
7694 部会108 韓国 14 09 Radiotherapy Daisuke TANII Department of Sinryougijutubu, Keijinkai byouin, Japan NEW APPROACH TO EASY AND ACCURATE MLC POSITION MEASUREMENT USING EPID * Fumihiro SASAKI, Takuya NAGASAKI, Ken MASUYAMA, Kazunori HOSOKI, Masayori ISHIKAWA, Hideki KOJIMA
7695 部会108 韓国 14 09 Radiotherapy Yon-Lae KIM Department of Radiology, Choonhae College of Health Sciences, Korea, Republic of DOSE DISTRIBUTION ACCORDING TO THE DOSE CALCULATION ALGORITHMS IN INHOMOGENEITY DENSITY * Tae-Suk SUH
7696 部会108 韓国 14 09 Radiotherapy Taejin HWANG Department of Radiation Oncology, Hallym University Medical Center, Korea, Republic of DOSIMETRIC EVALUATION OF PLANNING TARGET VOLUME MARGIN REDUCTION FOR PROSTATE CANCER VIA IMAGE-GUIDED INTENSITY-MODULATED RADIATION THERAPY * Sei-Kwon KANG, Kwang-Ho CHEONG, Soah PARK, Jai-Woong YOON, Taejin HAN, Haeyoung KIM, Meyeon LEE, Kyoung-Joo KIM, Hoonsik BAE, Tae-Suk SUH
7697 部会108 韓国 14 09 Radiotherapy Hiroyuki OKAMOTO Department of Radiation Oncology Division, National Cancer Center Hospital, Japan DOSIMETRIC IMPACT BY AN AIR PASSAGE FOR BRONCHUS CANCER IN BRACHYTHERAPY * Akihisa WAKITA, Satoshi NAKAMURA, Ako AIKAWA, Koji INABA, Jun ITAMI
7698 部会108 韓国 14 09 Radiotherapy Chang Yeol LEE Department of Department of Radiation Oncology, College of Medicine, Inha University, Korea, Republic of DOSIMETRIC EVALUATION OF AMPLITUDE-BASED RESPIRATORY GATING FOR DELIVERY OF VOLUMETRIC MODULATED ARC THERAPY (VMAT) * Hyun Do HUH
7699 部会108 韓国 14 09 Radiotherapy Joo-Young JUNG Department of Department of Biomedical Engineering and Research Institute of Biomedical Engineering, College of Medicine, Catholic University of Korea, Korea, Republic of EVALUATION OF ABSORBED DOSE FOR PERSON CLOSE TO THE CERVICAL CANCER PATIENT USING 192IR SOURCE FOR BRACHYTHERAPY * Sesik KANG, Tae Suk SUH
7700 部会108 韓国 14 09 Radiotherapy Jae-Hong JUNG Department of Radiation Oncology, College of Medicine, Soonchunhyang University, Korea, Republic of GLOTTIS ROTATIONAL ERRORS BY IMMOBILIZATION-MASK FOR GLOTTIS CANCER ON IMRT * Kwang Hwan CHO, Seong Kwon MOON, Sun Hyun BAE, Bo Young CHOE, Tae Suk SUH
7701 部会108 韓国 14 09 Radiotherapy Shusaku SATO Department of Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, Japan DEVELOPMENT OF A NEW X-RAY DOSE MONITORING SYSTEM FOR THE EYE LENS BY USING THE KINECT SENSOR SYSTEM * Takayuki KURATA, Ryohei FUKUYOSHI, Fukai TOYOFUKU
7702 部会108 韓国 14 09 Radiotherapy Naoyuki UKON Department of Medical Physics and Engineering, Graduate School of Medicine, Hokkaido University, Japan A FEASIBILITY STUDY ON REAL-TIME POSITRON MARKER TRACKING FOR RADIATION THERAPY * Masayori ISHIKAWA, Tomoyuki SATO, Kiyoto GOTOH, Kenneth SUTHERLAND, Naoki MIYAMOTO, Ryusuke SUZUKI, Koichi YASUDA, Norio KATOH, Hiroki SHIRATO
7703 部会108 韓国 14 09 Radiotherapy Min-Young LEE Department of Department of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Korea, Republic of DOSIMETRIC CONSIDERATIONS OF METAL ARTIFACT EFFECTS: EVALUATION OF DOSE DISTRIBUTIONS AFFECTED BY PATIENT TEETH AND IMPLANTS * Ji-Yeon PARK, Jeong-Woo LEE, Hae-Jin PARK, Sang-Won KANG, Tae-Suk SUH
7704 部会108 韓国 14 09 Radiotherapy Seheon KIM Department of Department of Biomedical Engineering, The Catholic University of Korea, Korea, Republic of THE NEED OF USING CT IMAGE IN GAMMA KNIFE TREATMENT PLANNING * Taeseok SEO
7705 部会108 韓国 14 09 Radiotherapy Seu-Ran LEE Department of Biomedical Engineering, The Catholic University of Korea, Korea, Republic of THE SOFTWARE DEVELOPMENT FOR RADIOTHERAPY PLAN EVALUATION INCLUDING RADIOBIOLOGICAL INDICES BASED ON MULTI-MODALITY IMAGES * Ji-Yeon PARK, Min-Joo KIM, Min-Young LEE, Tae-Suk SUH
7706 部会108 韓国 14 09 Radiotherapy Hideyuki MIZUNO Department of Radiation Therapy Quality Control Section, Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, Japan RECENT RESULTS OF A POSTAL DOSE AUDIT FOR RADIOTHERAPY MACHINE IN JAPAN WITH NON-REFERENCE CONDITION * Wataru YAMASHITA, Nobuhiro TAKASE, Suoh SAKATA, Mai FUKAHORI, Akifumi FUKUMURA
7707 部会108 韓国 14 09 Radiotherapy Jihye KOO Department of Radiation Oncology, Kyung Hee University Hospital at Gangdong, Korea, Republic of TO ENHANCE PLANNING QUALITY : CASE-SPECIFIC IMRT TREATMENT PLAN STANDARDS FOR LUNG CANCER BASED ON PLAN DATABASE * Myonggeun YOON, Wonkyu JUNG, Dongwook KIM
7708 部会108 韓国 14 09 Radiotherapy Weon Kuu CHUNG Department of Radiation Oncology, Kyung Hee University Hospital at Gangdong, Korea, Republic of DOSIMETRIC COMPARISION OF DIFFERENT RADIATION TREATMENT MODALITIES FOR ACOUSTIC NEUROMAS * Dong Oh SHIN, Dong Ho SHIN, Dong Wook KIM
7709 部会108 韓国 14 09 Radiotherapy Yuichi ONISHI Department of Radiation cancer treatment center, Social care corporation Koujin-kai Okayama Central Hospital, Japan COMPARISON OF DOSE ACCURACY FOR FILM AND TWO-DIMENSIONAL DETECTORS IN INTENSITY-MODULATED RADIATION THERAPY * Hajime MONZEN, Shinichi NAKAYAMA, Takeshi KAMOMAE, Souichirou KANESHIGE
7710 部会108 韓国 14 09 Radiotherapy Sang-Won KANG Department of Biomedical Engineering and Research Institute of Biomedical Engineering, College of Medicine, The Catholic University, Korea, Republic of DOSIMETRIC IMPACT OF ACUROS XB ALGORITHM WITH MATERIAL ASSIGNMENT IN VOLUMETRIC- MODULATED ARC THERAPY FOR ORAL CAVITY CANCER * Jeong-Woo LEE, Ji-Yeon PARK, Hae-Jin PARK, Min-Young LEE, Tae-Suk SUH
7711 部会108 韓国 14 09 Radiotherapy Sei-Kwon KANG Department of Radiation Oncology, College of Medicine, Hallym University, Korea, Republic of ACCUMULATED 4D DOSE BASED ON THE TWO END-PHASE DOSES * Jai-Woong YOON, Soah PARK, Taejin HWANG, Kwang-Ho CHEONG, Tae Jin HAN, Haeyoung KIM, Me-Yeon LEE, Kyoung Ju KIM, Hoonsik BAE
7712 部会108 韓国 14 09 Radiotherapy Hideyuki TAKEI Department of Proton Medical Research Center, University of Tsukuba, Japan CONTRIBUTION OF SCATTERED PHOTONS TO EPID IMAGE IN PHOTON THERAPY * Yusuke WATANABE, Tomonori ISOBE, Kenta TAKADA, Eisuke SATO, Hidetake HARA, Hiroshi MURAISHI, Tomoyuki HASEGAWA
7713 部会108 韓国 14 09 Radiotherapy Sungjin KIM Department of Physics, Yeungnam University, Korea, Republic of COMPARISON OF PENCIL BEAM, COLLAPSED CONE AND MONTE-CARLO ALGORITHMS IN RADIOTHERAPY TREATMENT PLANNING FOR 6MV PHOTON * Sungkyu KIM
7714 部会108 韓国 14 09 Radiotherapy Geum Seong CHEON Department of Department of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Korea, Republic of OPTIMIZATION OF PATIENT HEAD ANGLE POSITION TO SPARE HIPPOCAMPUS DURING THE WHOLE-BRAIN IMRT * Seong-Hee KANG, Tae-Ho KIM, Dong-Su KIM, Soo Yong KIM, Young Kyu LEE, Soo Yoon SUNG, Seon Mi PARK, Seung Chul LEE, Jisun JANG, Byeong Jin KIM, Ju Young HONG, Young-Nam KANG, Tae Suk SUH
7715 部会108 韓国 14 09 Radiotherapy Tae-Ho KIM Department of Department of Biomedical Engineering, Research Institute of Biomedical Engineering, College of Medicine, College of Medicine, The Catholic University of Korea, Korea, Republic of FEASIBILITY STUDY OF AN ABDOMINAL COMPRESSION DEVICE FOR RESPIRATORY CORRELATED RADIATION THERAPY * Seong-Hee KANG, Dong-Su KIM, Min-Seok CHO, Kyeong-Hyeon KIM, Siyong KIM, Tae Suk SUH
7716 部会108 韓国 14 09 Radiotherapy Sei-Kwon KANG Department of Radiation Oncology, College of Medicine, Hallym University, Korea, Republic of 4D TREATMENT PLANS BASED ON THE FREE BREATHING, AVERAGE AND MAXIMUM INTENSITY CT * Jai-Woong YOON, Soah PARK, Taejin HWANG, Kwang-Ho CHEONG, Tae Jin HAN, Haeyoung KIM, Me-Yeon LEE, Kyoung Ju KIM, Hoonsik BAE
7717 部会108 韓国 14 09 Radiotherapy Kanako OTOMO Department of Medical Physics, Graduate School of Medicine, Hokkaido University, Japan FUNDAMENTAL STUDY OF A NEW GATING IRRADIATION METHOD IN REAL-TIME TUMOR TRACKING RADIOTHERAPY (RTRT) SYSTEM BY USING MULTIPLE INTERNAL FIDUCIAL MARKERS * Naoki MIYAMOTO, Kennethe SUTHERLAND, Ryusuke SUZUKI, Taeko MASTUURA, Rikiya ONIMARU, Shinichi SHIMIZU, Hiroki SHIRATO, Masayori ISHIKAWA
7718 部会108 韓国 14 09 Radiotherapy Byung Jun MIN Department of Radiation Oncology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Korea, Republic of A SIMPLE DVH GENERATION TECHNIQUE FROM VARIOUS RADIOTHERAPY TREATMENT PLANNING SYSTEMS FOR INDEPENDENT HOSPITAL INFORMATION SYSTEM * Il Sun JEONG, Hyebin LEE, Heerim NAM
7719 部会108 韓国 14 09 Radiotherapy Taejin HWANG Department of Radiation Oncology, Hallym University Medical Center, Korea, Republic of AUTOMATICALLY GENERATED RECTAL DOSE CONSTRAINTS IN INTENSITY-MODULATED RADIATION THERAPY FOR PROSTATE CANCER * Yong Nam KIIM, Sei-Kwon KANG, Kwang-Ho CHEONG, Soah PARK, Jai-Woong YOON, Taejin HAN, Haeyoung KIM, Meyeon LEE, Kyoung-Joo KIM, Hoonsik BAE, Soo Kon KIM
7720 部会108 韓国 14 09 Radiotherapy Byung Jun MIN Department of Radiation Oncology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Korea, Republic of ASSESSING OF INTERNAL TARGET VOLUME BASED ON 4DCT AND CBCT IMAGES VARYING BREATHING PATTERNS FOR RADIOTHERAPY OF LUNG CANCER * Il Sun JEONG, Hyebin LEE, Heerim NAM
7721 部会108 韓国 14 09 Radiotherapy Shin-Wook KIM Department of Radiation Oncology, College of Medicine, the Catholic University of Korea,, Korea, Republic of THE FEASIBILITY STUDY OF MRI-BASED DOSE CALCULATION WITH LOOK UP TABLE IN RADIATION TREATMENT PLANNING * Hun Joo SHIN, Jae Choon LEE, Jina KIM, Sang Deok PARK, Ja Choon KOO, Soo Yeol LEE, Sang Hoon JI, Seok Gy JEON, Hong Seok JANG, Yeon Sil KIM, Byung Ock CHOI, Chul Seung KAY, Young Nam KANG
7722 部会108 韓国 14 09 Radiotherapy Hun-Joo SHIN Department of Department of Radiation Oncology, Incheon St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Korea, Republic of EVALUATION OF ELEKTA SYMMETRY 4D IGRT SYSTEM BY USING 4D LUNG MOVING PHANTOM * Jae-Hyuk SEO, Shin Wook KIM, Tae-Suk SUH, Young-Nam KANG
7723 部会108 韓国 14 09 Radiotherapy Sungbaek HUE Department of Neurosurgery, Ulsan University Hospital, University of Ulsan College of Medicine, Korea, Republic of EVALUATION OF SETUP UNCERTAINTY FOR BRAIN RADIOSURGERY PATIENTS USING EXACTRAC SYSTEM * Sung Ho PARK, Jun Bum PARK, Eun Suk PARK, In Uk LYO, Hong Bo SIM, Soon Chan KWON
7724 部会108 韓国 14 09 Radiotherapy Sungbaek HUE Department of Neurosurgery, Ulsan University Hospital, University of Ulsan College of Medicine, Korea, Republic of EVALUATION OF DOSE REDUCTION TECHNIQUES FOR 4D CT OF LUNG CANCER PATIENT * Sung Ho PARK, Jun Bun PARK, Eun Suk PARK, Soon Chan KWON, In Uk LYO, Hong Bo SIM
7725 部会108 韓国 14 09 Radiotherapy Dong Han KIM Department of Neurosurgery, Ulsan University Hospital, University of Ulsan College of Medicine, Korea, Republic of PRELIMINARY EVALUATION OF THE SETUP UNCERTAINTIES OF THE BRAIN STEREOTACTIC RADIOSURGERY PATIENTS WITH FRAMELESS MASK * Jun Bun PARK, Sung Ho PARK, Yeon HWANG, Eun Suk PARK, Soon Chan KWON, In Uk LYO, Hong Bo SIM
7726 部会108 韓国 14 09 Radiotherapy Yoshifumi OKU Department of Department of Health Sciences, Graduate School of Medical Sciences,, Kyushu University, Japan COMPARISON BETWEEN 2D AND 3D TREATMENT PLANNING WITH INTERFRACTIONAL ANATOMICAL VARIATIONS IN INTRACAVITARY BRACHYTHERAPY FOR CERVICAL CANCER * Hidetaka ARIMURA, Yoshiyuki HIRAKI, Masahiko TOYOTA, Yasumasa SAIGO, Mutsumi IKEDA, Takashi YOSHIURA, Hideki HIRATA
7727 部会108 韓国 14 09 Radiotherapy Yen Hwa LIN Department of Graduate School of Biomedical & Heath Sciences, Hiroshima University, Japan HIGH DOSE RATE VMAT MULTIPLE DIVIDED PARTIAL ARCS IN STEREOTACTIC LIVER RADIATION THERAPY * Shuichi OZAWA, Uranchimeg TSEGMED, Takeo NAKASHIMA, Shintaro TSUDA, Yusuke OCHI, Daisuke KAWAHARA, Takuro OKUMURA, Tomoki KIMURA, Yasushi NAGATA
7728 部会108 韓国 14 09 Radiotherapy Daisuke KAWAHARA Department of Clinical Support, Section of Radiation Therapy, hiroshima university, Japan USABILITY OF USING DIAPHRAGM MATCHING IN STEREOTACTIC BODY RADIOTHERAPY (SBRT) IN BREATH-HOLDING SBRT FOR LIVER CANCER * Shuichi OZAWA, Tatsuhiko SUZUKI, Yusuke OCHI, Rachel Yh LIN, Shintaro TSUDA, Yasushi NAGATA, Tomoki KIMURA
7729 部会108 韓国 14 09 Radiotherapy Joo-Wan HONG Department of Radiation Oncology, Seoul National University Bundang Hosptial, Korea, Republic of DOSIMETRIC IMPACT ON CHEST WALL BY RESPIRATORY MOTION DURING WHOLE BREAST RADIOTHERAPY: PHANTOM STUDY * Jin-Beom CHUNG, Cheol-Soo PARK
7730 部会108 韓国 14 09 Radiotherapy Yoon Hee LEE Department of School of Medicine, Kyung Hee University, Korea, Republic of DOSIMETRIC COMPARISON OF FOUR DIFFERENT EXTERNAL BEAM PARTIAL BREAST IRRADIATION TECHNIQUES * Dongwook KIM, Weonkyu CHUNG
7731 部会108 韓国 14 09 Radiotherapy Eunhee JEANG Department of Proton therapy center, National Cancer center, Korea, Republic of PLANNING PARAMETER OPTIMIZATION OF LUNG CANCER IN TOMOTHERAPY * Kwanghyun JO, Haksoo KIM, Meyoung KIM, Jonghwi JEONG, Chiyong JEONG, Jeonghoon PARK, Dongho SHIN, Sebyeong LEE, Youngkyung LIM
7732 部会108 韓国 14 09 Radiotherapy So-Hyun PARK Department of Radiation Oncology, Uijeongbu St.Mary’s Hospital, Korea, Republic of THE PHYSICAL AND BIOLOGICAL QA FOR INTENSITY-MODULATED ARC THERAPY ON THE HEAD AND NECK (H&N) CANCER * Seu-Ran LEE, Min-Joo KIM, Tae-Suk SUH
7733 部会108 韓国 14 09 Radiotherapy Kwang-Ho CHEONG Department of Dept. of Radiation Oncology, Hallym University College of Medicine, Korea, Republic of EVALUATION OF BREATHING PATTERNS FOR RESPIRATORY-GATED RADIATION THERAPY USING RESPIRATION REGULARITY INDEX * Me-Yeon LEE, Sei-Kwon KANG, Jai-Woon YOON, Soah PARK, Taejin HWANG, Haeyoung KIM, Kyoung Ju KIM, Taejin HAN, Hoonsik BAE
7734 部会108 韓国 14 09 Radiotherapy Jaiwoong YOON Department of Department of Radiation Oncology, College of Medicine, Hallym University, Korea, Republic of DEVELOPMENT OF A PATIENT SETUP MONITORING DEVICE BASED ON OPTICAL 3D SURFACE MEASUREMENT TECHNIQUE * Siyong KIM, Tae-Suk SUH, Kwang-Ho CHEONG, Sei-Kwon KANG, Soah PARK, Taejin HWANG, Haeyoung KIM, Hoonsik BAE, Me-Yeon LEE, Taejin HAN, Kyoung Ju KIM
7735 部会108 韓国 14 09 Radiotherapy Yuanjie CAO Department of Radiation Oncology, Korea University, Korea, Republic of SMART RT: A NOVEL PROGRAM FOR DOSIMETRICAL AND BIOLOGICAL EVALUATION OF RADIOTHERAPY TREATMENT PLANS * Suk LEE, Kyung Hwan CHANG, Jang Bo SHIM, Kwang Hyeon KIM, Jin Soo KO, Suk Woo CHOI, Sam Ju CHO, Sang Hoon LEE, Dae Sik YANG, Won Sup YOON, Young Je PARK, Chul Yong KIM
7736 部会108 韓国 14 09 Radiotherapy Yuanjie CAO Department of Radiation Oncology, Korea University, Korea, Republic of PATIENT PERFORMANCE-BASED PLAN PARAMETER OPTIMIZATION FOR PROSTATE CANCER IN TOMOTHERAPY * Suk LEE, Kyung Hwan CHANG, Jang Bo SHIM, Kwang Hyeon KIM, Hyun Do HUH, Sang Wook LIM, Young Je PARK, Dae Sik YANG, Won Sup YOON, Chul Yong KIM
7737 部会108 韓国 14 09 Radiotherapy Jang Bo SHIM Department of Radiation Oncology, Korea University, Korea, Republic of OPTIMIZED PLANNING TARGET VOLUME MARGIN IN HELICAL TOMOTHERAPY FOR PROSTATE CANCER: IS THERE A PREFERRED METHOD? * Suk LEE, Kyung Hwan CHANG, Yuanjie CAO, Kwang Hyeon KIM, Dae Sik YANG, Won Sup YOON, Young Je PARK, Chul Yong KIM
7738 部会108 韓国 14 09 Radiotherapy Yoshiki KUBOTA Department of Heavy Ion Medical Center, Gunma University, Japan DEVELOPMENT OF A MEASURING METHOD FOR PATIENT POSITIONING ERROR * Mutsumi TASHIRO, Ayaka SHINOHARA, Satoshi ABE, Saki KOBAYASHI, Ryosuke OKADA, Takayoshi ISHII, Tatsuaki KANAI
7739 部会108 韓国 14 09 Radiotherapy Kyung Hwan CHANG Department of Radiation Oncology, College of Medicine, Korea University, Korea, Republic of EVALUATION OF GEOMETRIC AND DOSIMETRIC ACCURACY FOR COUCH-BASED TRACKING SYSTEM (CBTS) * Suk LEE, Yuanjie CAO, Jang Bo SHIM, Kwang Hyeon KIM, Hyun Do HUH, Dongho SHIN, Yura CHO, Dae Sik YANG, Won Sup YOON, Young Je PARK, Chul Yong KIM
7740 部会108 韓国 14 09 Radiotherapy Yong Kyu LEE Department of Department of Radiation Oncology, Seoul St. Mary’s Hospital, The Catholic University of Korea, Korea, Republic of A STUDY OF THE CLINICAL USEFULNESS OF MODULATED ARC TREATMENT FOR NON-SMALL CELL LUNG CANCER * Ji Sun JANG, Geum Seong CHEON, Ji Na KIM, Jae Choon LEE, Byeong Jin KIM, Young-Nam KANG
7741 部会108 韓国 14 09 Radiotherapy Kyung Hwan CHANG Department of Radiation Oncology, College of Medicine, Korea University, Korea, Republic of DOSIMETRIC EVALUATION OF A WEEKLY BASED OFF-LINE ADAPTIVE RADIOTHERAPY USING KV-MVCT IN HELICAL TOMOTHERAPY * Suk LEE, Yuanjie CAO, Jang Bo SHIM, Kwang Hyeon KIM, Chul Kee MIN, Woo Chul KIM, Kwang Hwan CHO, Sangwook LIM, Nam Kwon LEE, Jung Ae LEE, Dae Sik YANG, Won Sup YOON, Young Je PARK, Chul Yong KIM
7742 部会108 韓国 14 09 Radiotherapy Sugruu KIMURA Department of Depertment of Medical Physics and Engineering, Hokkaido University, Japan QUALITY CONTROL OF A NEXT GENERATION REAL-TIME TUMOR-TRACKING RADIATION THERAPY SYSTEM – EVALUATION OF BASIC PROPERTIES FOR THE COLORED IMAGE INTENSIFIER AS A X-RAY IMAGER – * Naoki MIYAMOTO, Kenneth SUTHERLAND, Ryusuke SUZUKI, Hiroki SHIRATO, Masayori ISHIKAWA
7743 部会108 韓国 14 09 Radiotherapy Byungdo PARK Department of Department of Radiation Oncology, Samsung Changwon Hospital, Sungkyunkwan University School of Medicine, Korea, Republic of DOSIMETRIC IMPACT OF JAW TRACKING TECHNIQUE IN VOLUMETRIC MODULATED ARC THERAPY * Jeongwon KWAK, Byungchul CHO, Jonghoon KIM, Sangwook LEE, Seungdo AHN
7744 部会108 韓国 14 09 Radiotherapy Yuanjie CAO Department of Radiation Oncology, Korea University, Korea, Republic of DOSIMETRICAL AND RADIOBIOLOGICAL COMPARISON OF MULTI-MODALITY IMRT TECHNIQUES FOR PROSTATE CANCER * Suk LEE, Kyung Hwan CHANG, Jang Bo SHIM, Kwang Hyeon KIM, Sam Ju CHO, Sang Hoon LEE, Chul Kee MIN, Woo Chul KIM, Kwang Hwan CHO, Hyun Do HUH, Sang Wook LIM, Dong Ho SHIN, Jin Soo KO, Suk Woo CHOI, Dae Sik YANG, Young Je PARK, Won Sup YOON, Chul Yong KIM
7745 部会108 韓国 14 09 Radiotherapy Yong Ho KIM Department of Radiation Oncology, Pusan National University Hospital, Korea, Republic of EFFECT OF THE COLLIMATOR ANGLE ON THE RESULTS OF DOSIMETRIC VERIFICATION OF THE VOLUMETRIC MODULATED ARC THERAPY * Dahl PARK, Ha Ryung PARK, Won Taek KIM, Dong Won KIM, Yongkan KI, Juhye LEE, Jin Suk BAE, Hosang JEON, Ji Ho NAM
7746 部会108 韓国 14 09 Radiotherapy Boram LEE Department of Bio-convergence Engineering, College of Health Science, Korea University, Korea, Republic of DOSIMETRIC IMPACTS OF APPLICATOR HETEROGENEITY AND RISK ESTIMATION FOR SECONDARY CANCER : MONTE CARLO SIMULATION FOR IMAGE-GUIDED CERVICAL CANCER BRACHYTHERAPY * Myongguen YOON, Jiyeon PARK, Sunghwan AHN, Sunyoung LEE
7747 部会108 韓国 14 09 Radiotherapy Jong-Geun BAEK Department of Department of Physics, Yeungnam University, Korea, Republic of EVALUATION OF GEOMETRIC UNCERTAINTIES FOR SINGLE-FRACTION STEREOTACTIC RADIOSURGERY BY COMPARING THE TWO DIFFERENT MASK-CREATION METHODS * Young-Kee OH, Sung-Kyu KIM, Hyun-Soo JANG, Eng-Chan KIM
7748 部会108 韓国 14 09 Radiotherapy Jinho CHOI Department of Radiation Oncology, Gachon University, Gil Medical Center, Korea, Republic of THE EVALUATION OF TREATMENT PLAN FOR THE SBRT BY THE USING OF SMALL AND WEDGED FIELDS * So Hyun AHN, Kyu Chan LEE, Seok Ho LEE, Seung Heon LEE, Ki Hoon SUNG
7749 部会108 韓国 14 09 Radiotherapy Ji-Yeon PARK Department of Pediatrics, Stanford University School of Medicine, USA RECTAL DOSE VERIFICATION FOR PROSTATE RADIATION THERAPY WITH ENDORECTAL BALLOONS: RECTAL WALL DOSE MAP-GUIDED DOSIMETRIC EFFECTS ACCORDING TO DOSE OPTIMIZATION METHODS * Hae-Jin PARK, Sang-Won KANG, Min-Young LEE, Seung-Min PARK, Boram LEE, Seu-Ran LEE, Edward E GRAVES, Christopher H CONTAG, Tae-Suk SUH
7750 部会108 韓国 14 09 Radiotherapy Sang Hoon JUNG Department of Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Korea, Republic of A FEASIBILITY STUDY OF DETERMINATION OF INTERNAL TARGET VOLUME USING RESPIRATION-GATED MAGNETIC RESONANCE IMAGING IN RADIOTHERAPY FOR LIVER CANCER * Yoonsung CHUNG, Youngyih HAN, Hee Chul PARK, Do Hoon LIM, Doo Ho CHOI
7751 部会108 韓国 14 09 Radiotherapy Soon Sung LEE Department of Radiological Cancer Medicine, Korea University of Science & Technology, Korea, Republic of VALIDATION OF DEFORMABLE DOSE REGISTRATION USING B-SPLINE AND OPTICAL-FLOW ALGORITHM IN HEAD AND NECK CANCER PATIENTS * Sang Hyoun CHOI, Young Hoon JI, Mi-Sook KIM, Hyoung Jun YOO, Seungwoo PARK, Haijo JUNG, Chul -young YI, Su Chul HAN, Kum Bae KIM
7752 部会108 韓国 14 09 Radiotherapy Hosang JEON Department of Radiation Oncology, Pusan National University Yangsan Hospital, Korea, Republic of PATIENT SPECIFIC QUALITY ASSURANCE OF VOLUMETRIC MODULATED ARC THERAPY USING TWO-DIMENSIONAL ION CHAMBER ARRAY WITH ANGULAR DEPENDENCE CORRECTION * Dahl PARK, Yong Ho KIM, Ha Ryung PARK, Won Taek KIM, Dong Won KIM, Yongkan KI, Juhye LEE, Jinsuk BAE, Ji Ho NAM
7753 部会108 韓国 14 09 Others Hyounggun LEE Department of Department of Bio-convergence Engineering, Korea University, Korea, Republic of COMPARISON OF DOSES DEPOSITED IN NORMAL TISSUE BY DIAGNOSTIC AND SECONDARY RADIATION IN RADIOTHERAPY. * Dongwook KIM, Sungho PARK, Wonho LEE
7754 部会108 韓国 14 09 Others Hyun Jueng LEE Department of Physics, Yeungnam University, Korea, Republic of DETERMINATION OF THE OPTIMAL PHASE FOR THE RESPIRATORY GUIDED RADIOTHERAPY USING THE VISIBLE RESPIRATION GUIDING SYSTEM * Se An OH, Sung Kyu KIM, Ji Woon YEA
7755 部会108 韓国 14 09 Others Jina KIM Department of Biomedical Science, The Catholic University of Korea, Korea, Republic of DEVELOPMENT OF DIGITALIZED MOVING LUNG PHANTOM TO ESTIMATE THE CHANGE OF LUNG VOLUME IN RADIOTHERAPY * Hyung-Wook PARK, Sang-Hoon JI, Young-Nam KANG
7756 部会108 韓国 14 09 Others Woong CHO Department of Dept. of Radiation Oncology, Seoul National University Hospital, Korea, Republic of A RISK INDEX METHOD FOR THE EVALUATION OF RADIATION TREATMENT PLANS * Lei XING, Tae-Suk SUH, Hong-Gyun WU
7757 部会108 韓国 14 09 Others Hiroki OHTANI Department of Radiological Sciences, Tokyo Metropolitan University, Japan ISOLATION OF THE RADIOACTIVE CONTAMINATION PART USING RADIATION SHIELD PUTTY. * Takahiro HIRAYAMA
7758 部会108 韓国 14 09 Others Wol-Soon JO Department of Research Center, Dongnam Institute of Radiological & Medical Sciences, Korea, Republic of PRECLINICAL STUDY USING HUMAN CANCER CELL LINES FOR CLINICAL 6 MEV ELECTRON BEAM * Dong Hyeok JEONG, Jeuijin LIM, Kwangmo YANG, Sang Koo KANG, Dong Joo RHEE, Jung Kee KIM, Young Min MOON
7759 部会108 韓国 14 09 Others Hyunho LEE Department of Department of Bio-convergence Engineering, Korea University, Korea, Republic of THE PRESENT STATUS OF QUALITY ASSURANCE PROCEDURE IN KOREA * Seonghoon JEONG, Yunhui JO, Myonggeun YOON
7760 部会108 韓国 14 09 Others Satoru UTSUNOMIYA Department of Radiology, Graduate School of Medical and Dental Sciences, Niigata University, Japan CURRENT SITUATION OF THE MEDICAL PHYSICS RESIDENCY PROGRAM AT NIIGATA UNIVERSITY MEDICAL AND DENTAL HOSPITAL * Satoshi TANABE, Shinichi WADA, Takahide HAYAKAWA, Ryuta SASAMOTO, Toshifumi KASAHARA, Hidefumi AOYAMA
7761 部会108 韓国 14 09 Others Taewon NAM Department of Molecular Imaging Research Center, Korea Institute of Radiological and Medical Sciences, Korea, Republic of OPTIMIZATION OF A PROTOCOL OF WHOLE BODY IMAGING AND BLOOD SAMPLING FOR ABSORBED DOSE ESTIMATION IN CLINICAL RADIOIMMUNOTHERAPY WITH I-131 RITUXIMAB * Young Sub LEE, Hye Jin KANG, Dong-Yeop SHIN, Byung Hyun BYUN, Sang Moo LIM, Kyeong Min KIM
7762 部会108 韓国 14 09 Others Seung-Min PARK Department of Radiology, Stanford University, USA INTEGRATED NANOTECHNOLOGIES FOR COMPREHENSIVE CIRCULATING TUMOR CELL ANALYSIS * Dawson WONG, Chin-Chun OOI, Visham S NAIR, Ophir VERMESH, Adi GANI, Sanghun LEE, Susie SUH, Luke P LEE, Shan X WANG, Sanjiv S GAMBHIR
7763 部会108 韓国 14 09 Others N. SAOTOME National Institute of Radiological Science, Japan CHARACTERISTIC OF THE RANGE VERIFICATION SYSTEM USING SCINTILLATOR AND CCD CAMERA SYSTEM * Y. HARA, K. MIZUSHIMA, K. TANSHOU, Y. SARAYA, T. FURUKAWA, T. SHIRAI, K. NODA

Top of Page
会員ログイン
お問合せ
Twitter